Getting Started - Ribimex Ribiland PRPVC752AS User And Maintenance Manual

Submersible pump
Table of Contents

Advertisement

Available languages

Available languages

3. The supply cable should be checked periodically and before each use to see if there are any signs of
ageing or damage.
If the pump is not in good condition, do not use it. Have it repaired by an authorized centre.
4. If an extension is used, ensure that it is officially approved.
Keep power cord and extension cord well away from sharp edges, heat sources and combustibles.
5. The plug-in connector for the extension should be of the 2 pole + earth type of 10-16A/250V, in
accordance with EEC standards. The wire section in the cable should be equal to or greater than 1mm
The cable should not be lighter than cables of H05RN-F or H07RN-F type.
6. When disconnecting the power cable from the socket, always grip the plug itself and not the cable.
7. If the pump is used for emptying a pond, it should not be used when there are people in the pond.
8. When the pump is immersed, handling should not be carried out using the power cable, but using a
device (for ex. a rope) connected to the carrying handle.
9. Do not use power cable for carrying or hanging up the pump.
Use the transport handle.
IV. GETTING STARTED
Before any intervention on product, ensure that product is disconnected form its
power source.
4.1- Unpacking
- Remove product from its packaging.
- Check that product and accessories are not damage
4.2- Connecting the evacuation hose (Fig. 2 & 3)
1. Screw the universal fitting (connector) (3) provided onto the pump outlet (Fig.1).
2. Wedge the discharge hose on to the connection section corresponding to the internal diameter of
the hose (Fig.2).
3. Add a fixing collar (hose clamp not supplied) to complete the seal.
N.B.: For large diameter hoses and to obtain the optimum discharge output, it will be necessary to cut
the end of the universal fitting (3) so as to only keep the section suitable for the hose used (Fig.3).
Fig. 2
4.3- Adjusting the floating switch (Fig.4)
The float switch (4) has two positions :
- The "auto" position enables the automatic start of the pump.
When the water rises to reach approximately 160mm, the pump starts up.
When water level has lowered to approximately 55mm, the pump will stop automatically.
- The "manual" position allows to start and stop the pump by connecting the plug to the mains. The
water level for manual mode operation must be greater than 33mm.
4.4- Start-up
Note: Before use, clear the outlet line
Observe and respect minimum water level and max delivery height
Fig. 3
Fig.4
2
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

510896

Table of Contents