Hunter DDI Installation Manual page 8

Hide thumbs Also See for DDI:
Table of Contents

Advertisement

MOUNTING CONFIGURATION
INSTALLATION
CHANNEL HEIGHT
1 5/8"
1 5/8"
1 5/8"
1 3/8"
7/8"
3 1/4"
2 7/16'
K-BAR MOUNTING
Example of mounting to a trust
with standard mount hardware.
14
MATERIAL THICKNESS
MAXIMUM SPAN LENGTH
12 GA
84'
14 GA
72'
16 GA
60'
12 GA
60'
12 GA
30'
12 GA
240"
12 GA
156"
STRUT CHANNEL MOUNTING
If bracing is required unistrut can be used, we
recommend spanning at least three trusses
or perlins.
REMINDER
The retention cable should always
be secured around the building
structure or a beam, not around
something bolted on, such as a
strut channel.
STEP 1: MOUNTING
INSTALLATION
A
B
Select proper strut
Use strut channel or
channel from the chart.
similar to span three
points of the building
structure and create a
stable attachment point
for the fan.
NYLON LOCKING NUTS
STRUT CHANNEL
1/2" GRADE 5 BOLTS
WARNING: SUPPORT DIRECTLY FROM BUILDING STRUCTURE
C
Bolt fan mounting plate
to attachment point using
1/2" grade 5 bolts and
nylon locking nuts.
C
15