B Appendix - Electrical Panel Layout - Riello 20044636 Installation, Use And Maintenance Instructions

Forced draught gas burners
Table of Contents

Advertisement

B
Appendix - Electrical panel layout
Electrical system adjusted in factory
Key
CMV Motor contactor
DA
Control box (Landis RMG88.62A2)
F1
Filter to protect against radio disturbance
K1
Relay
I1
Switch: burner operation / stop
I2
Switch: 1st - 2nd stage
MB
Burner terminal strip
MV
Fan motor
PA
Air pressure switch
RT
Thermal relay
SM
Servomotor
SO
Ionisation probe
SP
Plug-socket
TA
Ignition transformer
TB
Burner earth
In the case of a phase/phase power supply, it is
necessary to install a jumper in the control box ter-
minal board, between clamp 6 and the earthing
WARNING
clamp.