Salutron D2X User Manual

Salutron D2X User Manual

Portable thickness gauge

Advertisement

Quick Links

U
S
E
R
´
S
 
M
A
U
S
E
R
´
S
 
M
A
SaluTron
P
O
R
T
A
P
O
R
T
A
T
H
I
C
K
T
H
I
C
K
G
A
U
G
G
A
U
G
N
U
A
L
N
U
A
L
®
D2X   
B
L
E
 
B
L
E
 
N
E
S
S
 
N
E
S
S
 
E
 
E
 

Advertisement

Table of Contents
loading

Summary of Contents for Salutron D2X

  • Page 1 ´   ´   ® SaluTron D2X               ...
  • Page 3: Table Of Contents

    2. Device Description  ____________________________________________________________________  5 3. Maintenance_________________________________________________________________________  6 4. Power Supply  ________________________________________________________________________  6 5. Measuring  _ __________________________________________________________________________  6   6. Work Modes of SaluTron D2X  ___________________________________________________________  7 7. Zeroing of the device __________________________________________________________________  9 8. Working with the menu ________________________________________________________________  9 8.1 Average (only in point measurement)  _ __________________________________________________  1 1 8.2 Reset _____________________________________________________________________________  1 2 8.3 Background  _ _______________________________________________________________________  1 2 8.4 Mode ...
  • Page 4: Preface

      User´s Manual – SaluTron D2X (Rel. 2.1)  1. Preface Thank you for choosing our product. You have purchased a product that meets precise specifications and  upholds globally recognized quality standards.  The purpose of this thickness gauge is to withstand the most demanding conditions, including temperature  variations, humidity, shock, dust, and vibration. Our rigorous testing standards, along with our unwavering  commitment to ensuring customer satisfaction, guarantee that you can rely on its quality at all times.  You can start using the device immediately, even without prior expertise, thanks to its user‐friendly design.  The device incorporates advanced technology, allowing you to effortlessly activate the extensive range of  additional functions.  Should  you  have  any  inquiries  regarding  thickness  measurements,  our  dedicated  distributors  or  we    ourselves are available to assist you.   SaluTron Messtechnik GmbH 4 ...
  • Page 5: Device Description

      User´s Manual – SaluTron D2X (Rel. 2.1)    2. Device Description     The  SaluTron D2X  coating  thickness  gauge  is  a  compact,  durable,  and  user‐friendly  device  optimized  for  your convenience. It is designed as a versatile tool with memory and interface capabilities, enabling non‐ destructive measurements on both magnetic (Fe) and non‐magnetic (NFE) metal surfaces (substrates).    The  FE  probe  is  specifically  designed  for  measuring  non‐magnetic  coatings,  including  lacquer,  plastic,  chrome, copper, zinc, enamel, etc., on steel or iron surfaces.    The NFe probe is intended for measuring insulating coatings, such as lacquer, plastic, enamel, etc., on non‐...
  • Page 6: Maintenance

      User´s Manual – SaluTron D2X (Rel. 2.1)    3. Maintenance  To achieve optimal results and ensure a long service life, it is crucial to handle the device properly. Please  follow these guidelines:   Avoid subjecting the device to strong shocks and prevent  the ingress  of dirt, chemicals, corrosive  substances, and water. This will help maintain its performance and accuracy.   Regularly clean the probes to ensure accurate measurements. Remove any dirt or paint from the  measuring head to prevent interference with readings.   If the device is not going to be used for an extended period, we recommend removing the batteries.  This will help preserve battery life and prevent potential damage due to battery leakage.   In the event of any faults or issues with the device or probes, please refrain from attempting repairs  on your own. Instead, we kindly request you to contact our service center. Our dedicated team will  be available to assist you and provide the necessary support.    By  adhering  to  these  guidelines,  you  can  ensure  optimal  performance,  longevity,  and  reliable  measurements from your coating thickness device.    4. Power Supply  This  gauge  is  powered  by  two  1.5V  AA  batteries.  These  batteries  provide  extended  usage  for  many ...
  • Page 7: Work Modes Of Salutron D2X

      User´s Manual – SaluTron D2X (Rel. 2.1)    Please refrain from measurements on magnets as they may produce inaccurate results. Additionally, to  prevent  any  potential  damage,  the  device  automatically  shuts  off  when  exposed  to  high  electrostatic  charges.    When the device is powered on and you press the    button, the SaluTron D2X will immediately power off. If the device is not used, it will automatically power  off after approximately three minutes. If the device is turned on without the probe screwed in, a blinking    probe icon  will appear on the display accompanied by an audible signal. After a brief period, the  device will automatically power off.      6. Work Modes of SaluTron D2X  The device can work in three work modes.      work mode: normal / continuous / memory         ...
  • Page 8   User´s Manual – SaluTron D2X (Rel. 2.1)    The active application (calibration of the probe) is shown in the figure after Ap. By pressing the button:    the information (date and comment) is shown for this application.              In  addition  to  the  basic  point  measurement  (without  storage),  you  can  also  perform  continuous  surface  measurements  ( )  with  this  device.  In  this  mode,  two  or  three  measurements  are  recorded  and ...
  • Page 9: Zeroing Of The Device

      User´s Manual – SaluTron D2X (Rel. 2.1)         7. Zeroing of the device  Special conditions, such as fluctuating temperatures, the introduction of new batteries, extended periods  of  non‐use,  or  variations  in  substrates  (surfaces),  can  potentially  impact  the  accuracy  of  the    measurements. In these instances, it is advisable to perform regular zeroing procedures. ‐ Press   in measuring mode.        ‐ Place the probe on the measuring foil. You will hear a beep.        ‐ Lift the probe at least 5 cm from the foil. You will hear a beep.    The zeroing is now complete. The device goes automatically into the measurement mode and is ready for  measurements.    The  following  section  of  the  manual  demonstrates  the  various  options  available  to  the  user,  including ...
  • Page 10   User´s Manual – SaluTron D2X (Rel. 2.1)    To select individual items, use the buttons:       and confirm your selection by pressing the    button. In the main menu, you can quickly navigate from the last item to the first item.        All four buttons have the function of arrow keys by which the input of data such as block numbers, limits    and comments are possible. Press          and the next character from the letters or digits line (e. g.  0,1,2,3 .. or A, B, C, D. ...) is shown. Pressing          pushes the cursor on the device display according to the left or right. If you press the arrow keys for more  than 2 seconds you can step quickly to the next input of scroll fast. For example, if you want to exceed the  limit by 125 µm, proceed as follows:    ‐ Press   or   as long until "1" is displayed.  ‐ With   you push the blinking cursor one place to the right.     ‐ Press   or    until "2" is displayed.    10 ...
  • Page 11: Average (Only In Point Measurement)

      8.1 Average (only in point measurement)  The  SaluTron  D2X  continuously  calculates  the  average  value  during  each  measurement  (excluding  the  storage  of  individual  measurements).  When  this  function  is  enabled,  the  average  value,  along  with  the  number  of  measurements,  will  be  displayed.  This  feature  is  particularly  valuable  when  dealing  with ...
  • Page 12: Reset

      User´s Manual – SaluTron D2X (Rel. 2.1)    surfaces that exhibit high roughness, where repeated measurements at the same point may yield different  values.  In  such  cases,  it  is  advisable  to  take  an  average  of  approximately  five  measurements  to  obtain  a  reliable result.      ‐ display of average value is on    On     ‐ display of average value is off    Off      8.2 Reset  This  item  allows  you  to  reset  the  mean  value,  which  is  recalculated  with  each  measured  value  and ...
  • Page 13: Unit

      User´s Manual – SaluTron D2X (Rel. 2.1)    number of the most recently accessed block. By modifying this number, you can access either an existing  block or create a new one (the number of the new block should be the number of existing blocks +1).    total:       2    actual:    2      Please ensure that the device only accepts valid input. For instance, if a block is assigned the number "0" or  a number greater than the total number of existing blocks +1, the display will show:    Block‐No. not    correct      When a new block is created, the date is automatically saved. Furthermore, it is possible to enter up to 12  characters  in  the  block  comment  field  (e.g.,  information  regarding  the  measurement  object),  which  will  also be saved.    B.Comment:    xxx… ...
  • Page 14: Limits

      User´s Manual – SaluTron D2X (Rel. 2.1)    ‐ for a correction press       and then   or  to change the time.    Confirm with  .           01/01/07  change‐ENTER  ‐ for a correction press       and then   or   to change the date.    Confirm with  .    If the displayed time and date are not to be corrected, the entry can be interrupted with  .     Note:  When replacing the batteries, please note that the set date and time will be lost. Therefore, it is necessary  to reset the time and date after battery replacement.    8.9 Limits  In  order  to  ensure  quality  assurance,  it  is  necessary  to  maintain  specific  upper  and  lower  limits  for  the ...
  • Page 15: Port

      User´s Manual – SaluTron D2X (Rel. 2.1)  ‐ Activate with Y‐Yes or N‐No.  Lower limit         0.0 µm   Limit down? N  ‐ Enter the lower limit value with     and   or  .  ‐ Activate with Y‐Yes or N‐No.  lower limit exceeded     upper limit exceeded  8.10 Port  This setting activates the corresponding output port of the SaluTron® D2X device. You have the option to  select either infrared transmission to a portable IR HP printer (using an IR adapter) or the traditional serial  interface, USB. If you choose the USB interface, please use the USB cable for the data transfer. For more  detailed  instructions,  refer  to  the  "FTDI  Driver  Installation  under  Windows"  section  for  additional  information.  The transmission format of the serial interface is as follows:  ‐ Baudrate:  9600  ‐ Datalength:  8 bits  ‐ Parity:  non  ...
  • Page 16   To  enable  these  specialized  measurements,  the  SaluTron  D2X  offers  a  total  of  16  application  memories.  Adjusting  the  device  for  these  unique  conditions  involves  conducting  four  measurements  at  different  layers across the entire range. ...
  • Page 17: Device

      User´s Manual – SaluTron D2X (Rel. 2.1)        ‐ Zero point: measure 4 x    State:  50.0 µm    change‐ENTER  ‐ for correction press   and then set the right foil value with  or .    ‐ Foil 1:  measure 4 x    State:  250 µm    change‐ENTER  ‐ for correction press   and then set the right foil value with   or  .    ‐ Foil 2:  measure 4 x      State:  700 µm    change‐ENTER  ‐ for correction press   and then set the right foil value with   or  .    ‐ Foil 3:  measure 4 x    The calibration process has been successfully completed and is now activated and stored in the application ...
  • Page 18: Additional Items In Memory Mode

      User´s Manual – SaluTron D2X (Rel. 2.1)    9. Additional Items in Memory Mode  9.1 Block  In  this  menu  item,  you  can  either  open  an  existing  block  or  create  a  new  one.  Please  refer  to  the  item  Mode section in this manual for more information.    9.2 Values  This submenu option provides the ability to view measurements for a specific block. The total number of  created blocks is displayed on the first line of the screen. The second line shows the current block, which is  the block where the most recent measurements were stored. To view the readings of a different block, use  the buttons   or   to enter the number of the desired block and confirm with  .    All:        3   ...
  • Page 19: Memo Delete

      User´s Manual – SaluTron D2X (Rel. 2.1)      ‐ Select Y‐Yes or N‐No with   or   and confirm with  .     9.4 Memo delete   This  menu  item  allows  you  to  delete  the  entire  memory,  including  the  measured  values  and  all  created  blocks with their associated comments.    All data    delete?    N    ‐ Select Y‐Yes or N‐No with   or   and confirm with  .    9.5 Statistic ...
  • Page 20: Print

      Fe 27  ‐ You can navigate through the statistical data by pressing the   or  .  9.6 Print  With the SaluTron D2X, you have the ability to print all measurements and statistics or transfer them to a  PC. This can be done using a portable infrared HP compatible printer (refer to the Port menu item in this  manual) or a serial printer connected via a USB/RS232 interface cable.  The measurement protocol and data can be transferred to a PC and saved into a file using a program and  an interface cable. Once saved, you can further process the data as needed.   If you select the "report" option, you will receive a listing in a format that can be directly read by programs  like  Excel.  The  required  software  can  be  found  on  our  homepage  at  www.salutron.de.  The  transmission  format for the serial interface is as follows:  ‐ Baudrate:  9600  ‐ Datalength:  8 Bit  ‐ Parity:  none   ‐ Stop bit:  1  ‐ Xon/Xoff:  active  To print out the protocol, follow these steps:  Report ...
  • Page 21   User´s Manual – SaluTron D2X (Rel. 2.1)  ‐ Enter examiner’s name (if necessary) with   or   and confirm with  .  Supplier:   xxxx ‐ Enter supplier’s name (if necessary) with   or   and confirm with  .  Costumer:  xxxx ‐ Enter customer’s name (if necessary) with   or   and confirm with  .  Object:  xxxx ‐ Enter object’s name (if necessary) with   or   and confirm with  .  Com.No:  xxxx ‐ Enter the commission number (if necessary) with   or   and confirm with  .  Charge.No:  xxxx ‐ Enter the batch number (if necessary) with   or   and confirm with  .  from bl:             1  till bl:                 2  ‐ Enter the number of the top block for the statistics with ...
  • Page 22: Technical Data

      User´s Manual – SaluTron D2X (Rel. 2.1)    ‐ Select Y‐Yes or N‐No with   or   and confirm with  .      All Blocks    together?     N  ‐ Select Y‐Yes or N‐No with   or   and confirm with  .    Histogram?          N    ‐ Select Y‐Yes or N‐No with   or   and confirm with  .    Print?       N      ‐ Select Y‐Yes or N‐No with   or   and confirm with  .    *) The histogram is a graphical representation of the processed data, resembling a Gaussian distribution.    Choosing  the  Measure  item  will  display  the  readings  in  a  table  (CSV)  format  for  the  output.  This  print ...
  • Page 23   User´s Manual – SaluTron D2X (Rel. 2.1)  0.01mm  in  the  range  of  1.00  ‐  2.00  or  mm  0.01 mil in the range of 0.00 ‐ 9.99 mil  or  0.1 mil in the range of 10.0 ‐ 32 mil  0.01 mil in the range of 0.00 ‐ 9.99 mil  0.1 mil in the range of 10.0 ‐ 80.0 mil  Minimum  thickness of the  0.20 mm or 8 mil  0.05 mm or 2 mil  base material  Repetitive  ± (1.5 µm + 2%) or ± (0.06 mil +2%)  accuracy  Minimum  10 x 10 mm or 0,4" x 0,4"  measuring area  Memory  8192 locations  Blocks  optional in the range of memory’s capacity  ‐ Storage:   ‐10°C to 60°C or 14°F to 140°F     Temperature  ‐ Operating:   0°C to 60°C or 32°F to 140°F  Probes  One‐Point  Interface ...

Table of Contents