Mini GlossTector 60°
Operations Manual

Advertisement

Table of Contents
loading

Summary of Contents for Salutron Mini GlossTector 60

  • Page 1 Mini GlossTector 60° Operations Manual...
  • Page 3: Table Of Contents

    Table of Content 1 PRODUCT DESCRIPTION ....................4 2 SAFETY ..........................4 3 GENERAL INFORMATION ....................4 4 POWER SUPPLY........................5 5 OVERVIEW ........................... 6 6 GETTING STARTED ......................6 6.1 T .......................... 6 URN ON 6.2 C ........................6 ALIBRATION 6.3 T ...........................
  • Page 4: Product Description

    Please take out the battery if you do not use the instrument for a longer period of time. 3 General information • Before using the mini GlossTector 60° we strongly advice you to read the instructions’ manual. • After receiving a delivery, we ask you to check whether everything is included and not damaged.
  • Page 5: Power Supply

    • Please note that batteries are special waste and should therefore not be disposed with regular trash but should be brought to special collection points. • Keep the cailbration board clean! Any dust, dirt or oil may lead to false measurement results.
  • Page 6: Overview

    6 Calibration board 6 Standard Deviation 6 Getting started 6.1 Turn on Turn on the mini GlossTector 60° by shortly pressing the main button. 6.2 Calibration When the instrument is placed in the holder it automatically enters calibration mode. The display shows CAL. When the main button gets pressed the instrument calibrates to 97.0...
  • Page 7: Testing

    When the instrument is not placed in the holder it is automatically ready for testing. The display shows TEST. Please make sure that the instrument is calibrated (see 6.2). Place the mini GlossTector 60° on the working piece flat and stable. It is important that the aperture is completely covered by the working piece.
  • Page 8: Data Transfer

    10 Error notifications Calibration error: Clean the calibration standard and the lens (carefully!) using ethanol or cleaning alcohol. If the calibration should still not work contact Salutron Messtechnik GmbH, our technical assistance is happy to help. Wrong results: If the gauge should display wrong results calibrate it and try again. If the results should still be wrong contact Salutron Messtechnik GmbH, our technical assistance is happy to help.
  • Page 9: Standards

    12 Standards ISO2813 Paints and varnishes -- Determination of secular gloss of non- metallic paint films at 20 degrees, 60 degrees and 85 degrees. ASTM D 523 Standard test method for secular gloss. DIN 67530 The reflect meter as an aid in evaluating gloss on level paint and plastic surfaces.