1-5-10 Others
(1) Detaching and refitting the main motor
Procedure
1. Remove the right cover (See page 1-5-
3).
2. Remove the connector.
3. Remove the M3 screw and two M4
screws.
4. Remove the main motor.
5. Check or replace the main motor and
refit all the removed parts.
Y113860-1
1-5-49
2MH/2MJ/2MK/2ML
Connector
M4 screws
Figure 1-5-74
Sevice Manual
Main motor