Installation, operation and maintenance instructions

High voltage flameproof motors for explosive atmosphere
AMD Rg 355-400-450-500
Machine foundation and mounting – Vertical mounting arrangements
Mounting arrangement
The general rules for foundation and mountings are similar to the rules for horizontal mounting arrangement. See Sheet
No 3AAM101029. In general, vertical machine are mounted on a separately prepared steel foundation plate.
Installation on a steel foundation plate
Check fastening holes in steel foundation plate, clean seating surfaces, set down machine and align.
Couple machine and bolt up in operating location. Tighten holding down bolts uniformly, working in opposite pairs.
The machine must rest squarely on its fastening flange around the whole circumference.
After the final checks dowel the motor on the steel plate.
1.
Machine fastening flange
2.
Steel foundation plate
3.
Holding down bolt
Sheet No.
3AAM101030 E
Rev. B
01.2023
Page 1 of 1
Issued by: MOLM