Display Defect Description
H1
Motor high
temperature
H2
Control board high
temperature
H3
Control board
super high
temperature
LR
Over current
S1
Short circuit
Solutions
1. Stop riding or ride scooter at low speed,
avoid climbing.
2. Check whether the motor wire is
damaged, and whether the temperature
signal wire of the motor wire is short-
circuited to the ground.
3. Replace the motor.
1. Stop riding or ride scooter at low speed,
avoid climbing.
2. Check the installation of control board
radiator.
3. Replace the control board.
1. Stop riding or ride scooter at low speed,
avoid climbing.
2. Check the installation of control board
radiator.
3. Replace the control board.
1. Release the accelerator.
2. Restart.
3. Replace the control board.
1. Get the motor disconnected and restart
scooter. If this alarm has not been
cleared, get control board replaced;
otherwise, all-clear, replace the motor.