Aiwa -09CHSRINV/TP11 Service Manual page 52

Inverter air conditioner
Table of Contents

Advertisement

3.2.14 P7---Overheating protection on Cooling mode
On heating mode, when IDU evaporator coil temperature IPT≥62
P7 failure code.
Display P7
ODU fan motor
works normal?
Yes
Sensor loosing
from connector?
Yes
The sensor open
or short circuit?
Yes
Replace IPT sensor
Yes
P7 disappear?
No
Replace IDU PCB
End
Air Conditioner Service Manual
No
Fan motor
broken?
No
Re-connect sensor
No
, ODU PCB will switch off outdoor unit and show
Yes
Replace fan motor
No
P7 disappear?
P7 disappear?
No
Yes
Yes
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aiwa-12chsrinv/tp11Aiwa-18chsrinv/tp11

Table of Contents