Aiwa -09CHSRINV/TP11 Service Manual page 47

Inverter air conditioner
Table of Contents

Advertisement

3.2.9 P1---
Over / under voltage protection
1. Test voltage between L &N, When the power supply V>AC260V or V<AC150V, AC will display P1 protection,
unit will recover back to previous status while V>AC155V.
2. Test voltage on the big size electrolytic capacitor of ODU PCB, When DC busbar voltage V>DC420V or V
<DC150V, unit will recover back to previous status while DC190V<V<DC410V
Air Conditioner Service Manual
Display P1
Is the power supply
voltage btw145-260V?
Yes
Is the busbar voltage
btw150-420V?
Yes
Replace ODU PCB
End
Wait until the AC
No
voltage recovery
Is the power supply
voltage btw145-260V?
No
Wait until the busbar
No
voltage recovery
Unit works
normal?
No
Yes
Yes
50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aiwa-12chsrinv/tp11Aiwa-18chsrinv/tp11

Table of Contents