POP UP EIGER 500 Instruction Manual

Double & single width 3t

Advertisement

Quick Links

I N S T R U C T I O N M A N U A L
F O R EI G ERT OW E R
EIGER
500
DOUBLE & SINGLE WIDTH 3T
INSTRUCTION MANUAL EN 1004-2-en
(Rev.03 02-12-2022)
info@popupproducts.co.uk
popupproducts.co.uk
+44 (0)1244 833 933

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EIGER 500 and is the answer not in the manual?

Questions and answers

Summary of Contents for POP UP EIGER 500

  • Page 1 I N S T R U C T I O N M A N U A L F O R EI G ERT OW E R EIGER DOUBLE & SINGLE WIDTH 3T INSTRUCTION MANUAL EN 1004-2-en (Rev.03 02-12-2022) info@popupproducts.co.uk popupproducts.co.uk +44 (0)1244 833 933...
  • Page 2: Table Of Contents

    F OR E IG E R 50 0 D O UB L E & S I N G L E W I DT H 3 T CONTENTS CONTENTS EIGER 500 4.2M DW - ASSEMBLY INTRODUCTION EIGER 500 3.7M SW - ASSEMBLY...
  • Page 3: Introduction

    Only original Pop Up Products EIGERTOWER components, in undamaged condition as specified in this instruction manual, shall be used to assemble this access tower. Pop Up Products Limited cannot accept responsibility in the event of an accident occurring because of mixing components from different manufacturers.
  • Page 4: Know Your Eigertower

    KNOW YOUR EIGERTOWER PA R TS LI S T I N G 4 RUNG FRAME ADJUSTABLE LEG & CASTOR HATCH PLATFORM 2 RUN G LAD DER FR AME DI AG ON AL B R A C E 4 RUNG LA DD ER F RAME HOR IZO NT A L B R A C E STANDARD PLATFORM TOEBOARD...
  • Page 5: Know Your Eigertower's Components

    KNOW YOUR EIGERTOWER COMPONENTS Claw 1 BRACES Both horizontal and diagonal braces are fitted with triggered hooks at both ends. The triggers, when operated, pull back to allow the hook to be placed over the tubing used on the tower. Horizontal braces are also used as guardrails. All brace hooks (Except the first base assembly braces) must be attached to the top of the frame horizontal tube.
  • Page 6 Ensure all safety decals are present, intact and readable. A detailed Inspection Guide is available. To obtain a copy of this guide, please contact POP UP Products. Threads, hinges and brace claws may be lubricated with light oil to ensure correct functionality is maintained.
  • Page 7: Know Your Kit List And Specifications

    KNOW YOUR KI T LIST AND SPECIFICATIONS Page 6...
  • Page 8 KNOW YOUR KI T LIST AND SPECIFICATIONS Page 7...
  • Page 9: Safety Dos And Don'ts - Always

    SAFETY DOS AND DON’TS - ALWAYS Always read and understand this guide before you begin assembly. Always ensure that all safety requirements are met and that EIGERTOWER is the correct access solution for the task you wish to perform. Always ensure that EIGERTOWER is assembled and dismantled by a qualified, competent person. Always cordon off...
  • Page 10: Safety Dos And Don'ts - Never

    SAFETY DOS AND DON’TS - NEVER Never use EIGERTOWER if you don’t understand something in this guide; please contact the supplier for advice. Never assemble, use, move or dismantle EIGERTOWER if you are tired or unwell or if you are under the influence of alcohol or drugs.
  • Page 11: Before You Start

    BEFORE YOU START PREPARATION The floor area must be clear of any obstructions including materials and debris. Check that you have all the components necessary to construct the tower height you require. Check also each component for condition and correct function. If any part is missing or damaged/not working correctly it must be replaced before assembling 3T (THROUGH THE TRAPD OOR) SYSTEM The 3T method of construction has been developed to reduce the risk of an erector falling from a tower during construction.
  • Page 12: Getting Started

    MIN. GETTING STARTED The Eiger 500 tower is available in two base sizes, 1450mm by a 1.8m or 2.5m platform length. The tower will be supplied with various height frames and you must always start with the smallest size frames first. The following instructions deal with a tower using 2 rung frames at the start, if supplied with 3 rung frames instead of 2 rung, start with the 3 rung frames.
  • Page 13: Eiger 500 4.2M Dw - Assembly

    EIGER 500 3T ASSEMBLY GUIDE STEP 6 DOUBLE WIDTH 1450 TOWER 4.2M PLATFORM HEIGHT Attach four stabilisers, one to each corner of the tower. Place the upper THROUGH THE TRAPDOOR (3T) SYSTEM coupler of the stabiliser under the third rung of the frame and the lower coupler This method of construction reduces the risk of a fall from height.
  • Page 14: Eiger 500 3.7M Sw - Assembly

    EIGER 500 3T ASSEMBLY GUIDE STEP 6 SINGLE WIDTH 850 TOWER 3.7M PLATFORM HEIGHT Attach four stabilisers, one to each corner of the tower. Place the upper THROUGH THE TRAPDOOR (3T) SYSTEM coupler of the stabiliser under the third This method of construction reduces the risk of a fall from height. You will complete rung of the frame and the lower coupler an ‘assembly / access’...
  • Page 15: 10 Point Pre-Use Safety Checklist

    10 POINT PRE-USE SAFETY CHECKLIST 10 POINT PRE-USE CHECKLIST FOR USERS BEFORE USE Ensure tower is correct, complete and level. COMPONENTS Check all components are free from damage. CASTORS Ensure they are locked. ENVIRONMENT No environmental changes have influenced the safe use of your tower. STABILISER COUPLER CLAMPS Check they are secure &...
  • Page 16: Registrations

    REGISTRATIONS EN 1004 ISO 9001 Class 3 Page 15...
  • Page 17 po p u ppro ducts.co .uk +4 4 ( 0 ) 1244 833 933 i nfo @popup pro ducts .co.uk...

Table of Contents