en Troubleshooting
Fault
The drying time is too
long.
Water is leaking from
the appliance.
The laundry is too
damp.
54
Cause and troubleshooting
The ambient temperature is lower than 15 °C.
Ensure that the ambient temperature is above 15
°C.
Insufficient air circulation at the appliance's installation
location.
Ventilate the appliance's installation location.
The appliance's ventilation opening is blocked.
Ensure that the ventilation opening of the appliance
is kept clear.
Heat exchanger is soiled.
Running the basic appliance care programme on
the appliance.
→ "Running the basic appliance care programme
on the appliance", Page 42.
Automatic self-cleaning function rinses the appliance's
heat exchanger.
Not a fault.
1.
Do not pull out the condensation tank.
2.
Do not cancel the programme.
3.
Appliance is not correctly aligned.
→ "Aligning the appliance", Page 16
The seal for the heat exchanger cover is dirty.
Clean the seal for the heat exchanger cover.
→ "Cleaning the base unit", Page 47
Water drain hose is not connected correctly.
Ensure that the water drain hose is connected cor-
rectly.
→ "Connecting the water drain hose", Page 14
The lever for the heat exchanger cover is not closed
correctly.
Ensure that the lever for the heat exchanger cover
is closed correctly.
→ "Closing the base unit", Page 48
Unsuitable programme for the type of fabric.
Set a timed programme for the subsequent drying.
→ "Programmes", Page 26
There has been a power cut.
Check whether the lighting in your kitchen or other
appliances are working.
The load is too large.