Siemens WQ56A4D01W User Manual And Installation Instructions page 53

Table of Contents

Advertisement

Fault
⁠ and programme
terminated.
Condensation in the
condensation tank
even though the water
drain hose is connec-
ted.
The programme does
not start.
The length of the pro-
gramme changes dur-
ing the drying cycle.
Pumping noise.
Buzzing noise.
The drying time is too
long.
Cause and troubleshooting
Rinse the water drain hose with tap water.
The filter for the condensation tank is soiled.
→ "Clean the filter for the condensation tank.",
Page 49.
Foreign object is located in the base unit
→ "Opening the base unit", Page 47.
1.
Remove the foreign objects that are present.
2.
→ "Closing the base unit", Page 48.
3.
Dirt in the appliance.
Preparing the appliance for the intensive appliance
care programme.
→ "Preparing the appliance for the intensive appli-
ance care programme", Page 43.
The appliance uses condensation for the automatic
self-cleaning.
Not a fault – no action required.
Water drain hose is not connected correctly.
Ensure that the water drain hose is connected cor-
rectly.
→ "Connecting the water drain hose", Page 14
Childproof lock is activated.
→ "Deactivating the childproof lock", Page 34
You have not pressed 
Press
⁠ .
No programme set.
→ "Setting a programme", Page 30.
1.
→ "Starting the programme", Page 30.
2.
The programme operation is optimised electronically.
This may change the programme duration.
Not a fault – no action required.
Condensation pump active.
Not a fault – normal operating noise.
Compressor ventilation active.
Not a fault – normal operating noise.
Fluff filter is soiled.
→ "Cleaning the fluff filter", Page 31
The ambient temperature is greater than 30 °C.
Ensure that the ambient temperature is lower than
30 °C.
Troubleshooting en
⁠ .