Clearances - Access in Service

1. A flat vertical area is required for the installation of the boiler.
2. These dimensions include the necessary clearances around
the boiler for case removal, spanner access and air movement
(Figs. 9 & 10). Additional clearances may be required for the
passage of pipes around local obstructions such as joists
running parallel to the front face of the boiler.
*These are MINIMUM recommended dimensions. Greater
clearance will aid installation and maintenance.
Before Installation
5
5mm Min
190mm
625mm
35mm Min*
in Cupboard
120mm Min*
5mm Min
35mm Min* in
cupboard (cut-outs
required for
pipework)
85mm Min* below
ceiling (allows
access to
compression
fittings on pipe)
625mm
35mm Min*
in Cupboard
120mm Min*
Assure Heat
29