Siemens ST950ELV Handbook page 127

Table of Contents

Advertisement

Figure 56 - Fault Table on completion of restoration from Heart
Restoring from the Heart Using WIZ
It is only possible to restore the most recent Restore Point when using WIZ. To start
the operation, invoke WIZ from the handset command line and select the Heart
menu item from the top level WIZ menu.
The user is presented with a sub-menu containing the following two options.
1> Own Heart
2> Restore
Select option 2.
The controller reads the available restore points from the Heart and outputs the
following. NOTE : The restore point name shown below is representative of a typical
restore point.
Restore from:
ST950-LV32B
Y/N?
Selecting "N" will display the following.
Restore not
started.
Press any key
Pressing any key returns to the original sub-menu. If no key is pressed, the user is
automatically returned to the sub-menu after a few seconds.
Selecting "Y" will display the following.
Switch signals off
and press the PRG
button.
Security classification
Unrestricted
Version
7
Last Editor
manpreet.jeerh
Document Name
ST950 ICM Handbook
Copyright © Siemens plc 2020. All Rights Reserved.
All manuals and user guides at all-guides.com
Mobility is a division of Siemens Plc
Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Page
127 of 154
Status
Issued
Date
January 2020
Document No.
667/HE/45950/000

Advertisement

Table of Contents
loading

Table of Contents