SIMATIC HMI
IWP10F Mobile WebClient - Quick Install Guide
Product Information
A5E52612569
Validity
These Product Information apply to the "IWP10F Mobile WebClient" HMI device with article number 6AV2145-6KM00-0AA0.
This Product Information describes the general commissioning of the "IWP10F Mobile WebClient" HMI device. Before setting up and commissioning the system, refer to the "IWP10F Mobile WebClient"
operating instructions for a description of the safety functions and other information. You can find the current operating instructions on the internet
(https://support.industry.siemens.com/cs/ww/en/view/109817011).
Required system components
IWP10F Mobile WebClient HMI device
Article number 6AV2145-6KM00-0AA0
You can find ordering information on the Internet (https://mall.industry.siemens.com).
Installing connection boxes
Use the Product Information provided for the connection box for installation.
1. Mount the connection box.
2. Set a unique box ID.
3. Connect the protective conductor.
4. Connect the cables for the EMERGENCY STOP button and acknowledgment button with your
processing unit.
5. Connect the connection box with PROFINET (LAN).
6. Connect the cables for the power supply.
Connecting the connecting cable to the IWP10F Mobile WebClient
1.
If necessary, open the connection compartment. Loosen
the seven marked PT screws until you can remove the
connection compartment cover.
2.
Remove the connection compartment cover.
Connect IWP10F Mobile WebClient and set up server connection
IWP10F Mobile WebClient - Quick Install Guide
A5E52612569-AA, 02/2023
Connecting cable
Article numbers 6XV1440-4B...
3.
Grease the fin seal of the connecting cable, e.g. with
Vaseline, and insert the connecting cable into the
corresponding guide as illustrated.
4.
Connect the 12-pin plug-in connector to the X51 interface.
Observe the mechanical coding of the connector.
Connection box compact, connection box standard or connection box advanced:
Article number 6AV2125-2AE03-0AX0, 6AV2125-2AE13-0AX0 or 6AV2125-2AE23-0AX0
5.
Connect the RJ45 connector to the X3 interface. Make
sure that the RJ45 connector audibly engages.
6.
Close the connection compartment. Place the connection
compartment cover onto the connection compartment
and tighten the screws of the connection compartment
cover with a torque of 0.8 Nm.