Replacing The Battery - Fluke 87V/IMSK User Manual

Table of Contents

Advertisement

80 Series V
Users Manual
Good F2 fuse: 00.0 Ω to
00.5 Ω
Replace fuse: OL
Touch top half
of input contacts
Good F1 fuse: 0.995 kΩ to
1.005 kΩ
Replace fuse: OL
Figure 10. Testing the Current Fuses
36

Replacing the Battery

87 V
TRUE RMS MULTIMETER
Replace the battery with a 9 V battery (NEDA A1604,
6F22, or 006P).
˚
C/
˚
F
MIN MAX
RANGE
AutoHOLD
Peak MIN MAX
REL
Hz %
4½ DIGITS
1 Second
mV
mA
A
V
A
LO
LO
V
OFF
A
mA
A
COM
V
400mA
FUSED
10A MAX
FUSED
Replace the battery as follows, refer to Figure 11:
87 V
TRUE RMS MULTIMETER
1.
˚
C/
˚
F
MIN MAX
RANGE
AutoHOLD
Peak MIN MAX
2.
Remove the battery door by using a standard-blade
REL
Hz %
4½ DIGITS
1 Second
mV
mA
A
V
A
LO
LO
V
OFF
3.
A
mA
A
COM
V
400mA
FUSED
10A MAX
FUSED
aom5f.eps
W
Warning
X
To avoid false readings, which could lead to
possible electric shock or personal injury,
replace the battery as soon as the battery
indicator (b) appears. If the display shows
bAtt the Meter will not function until the
battery is replaced.
Turn the rotary switch to OFF and remove the test
leads from the terminals.
screwdriver to turn the battery door screws one-
quarter turn counterclockwise.
Replace the battery and the battery door. Secure the
door by turning the screws one-quarter turn
clockwise.