10. Electrical characteristics

Model name
Voltage
Power
supply
Frequency
Max operating current*
Starting current
Circuit breaker current
Power cable
Wiring
2
spec.*
Connection
3
cable*
*1: Maximum current is the total current of the indoor unit and the outdoor unit.
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate de-
vices complied to the regional standard.
*3: Limit voltage drop to less than 2%. Increase conductor size if voltage drop is 2% or more.
1
Cross-sectional area
Limited wiring length
AOYG30KMTA
V
Hz
A
21.0
A
10.2
A
2
mm
2
mm
m
- 49 -
AOYG36KMTA
230 ~
50
21.5
13.9
25
4.0
1.5
51