Fujitsu ASYG36KMTA Design & Technical Manual
Fujitsu ASYG36KMTA Design & Technical Manual

Fujitsu ASYG36KMTA Design & Technical Manual

Hide thumbs Also See for ASYG36KMTA:
Table of Contents

Advertisement

AIR CONDITIONER
Wall mounted type
DESIGN & TECHNICAL MANUAL
INDOOR
OUTDOOR
ASYG30KMTA
ASYG36KMTA
AOYG30KMTA
AOYG36KMTA
DR_AS110EF_03
2020.11.19

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ASYG36KMTA

  • Page 1 AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG30KMTA ASYG36KMTA OUTDOOR AOYG30KMTA AOYG36KMTA DR_AS110EF_03 2020.11.19...
  • Page 2 • Product specifications and design are subject to change without notice for future improvement. • For further details, please check with our authorized dealer. Trademarks The following term and logo are trademarks of Fujitsu General Limited in the United States, other countries or both: ™...
  • Page 3: Table Of Contents

    CONTENTS Part 1. INDOOR UNIT................1 1. Specifications....................2 2. Dimensions....................4 2-1. Models: ASYG30KMTA and ASYG36KMTA..............4 3. Wiring diagrams ....................6 3-1. Models: ASYG30KMTA and ASYG36KMTA..............6 4. Capacity table....................7 4-1. Cooling capacity.......................7 4-2. Heating capacity ......................8 5. Fan performance ...................9 5-1. Air velocity distributions....................9 5-2.
  • Page 4 CONTENTS (continued) Part 2. OUTDOOR UNIT..............35 1. Specifications....................36 2. Dimensions....................37 2-1. Models: AOYG30KMTA and AOYG36KMTA..............37 3. Installation space ..................38 3-1. Models: AOYG30KMTA and AOYG36KMTA..............38 4. Refrigerant circuit ..................41 4-1. Models: AOYG30KMTA and AOYG36KMTA..............41 5. Wiring diagrams ..................42 5-1. Models: AOYG30KMTA and AOYG36KMTA..............42 6.
  • Page 5: Part 1. Indoor Unit

    Part 1. INDOOR UNIT WALL MOUNTED TYPE: ASYG30KMTA ASYG36KMTA...
  • Page 6: Specifications

    1. Specifications Wall mounted Type Inverter heat pump Model name ASYG30KMTA ASYG36KMTA Power supply 230 V ~ 50 Hz Power supply intake Outdoor unit Available voltage range 198—264 V Rated Btu/h 27,300 32,100 Cooling 2.9—9.0 2.9—10.0 Min.—Max. Btu/h 9,900—30,700 9,900—34,100 Capacity 10.1...
  • Page 7 Specifications for ErP Lot 10 Model name ASYG30KMTA ASYG36KMTA Cooling Energy efficiency class Heating (Average) Cooling 8.00 9.40 Pdesign Heating (Average) 6.50 7.10 SEER Cooling 6.67 6.14 kWh/kWh SCOP Heating (Average) 4.54 4.52 Annual energy consumption kWh/a QHE (Average) 2,001...
  • Page 8: Dimensions

    2. Dimensions 2-1. Models: ASYG30KMTA and ASYG36KMTA Unit: mm 1,150 1,150 Outline of unit - 4 - 2-1. Models: ASYG30KMTA and ASYG36KMTA 2. Dimensions...
  • Page 9 ¢ Installation space requirement Provide sufficient installation space for product safety. Unit: mm Outline of unit 50 or more 50 or more 70 or more 140 or more 1,500 or more - 5 - 2-1. Models: ASYG30KMTA and ASYG36KMTA 2. Dimensions...
  • Page 10: Wiring Diagrams

    3. Wiring diagrams 3-1. Models: ASYG30KMTA and ASYG36KMTA - 6 - 3-1. Models: ASYG30KMTA and ASYG36KMTA 3. Wiring diagrams...
  • Page 11: Capacity Table

    6.04 4.78 2.44 6.18 4.79 2.48 6.52 5.02 2.52 6.87 5.24 2.56 7.25 5.41 2.60 7.83 5.67 2.65 ¢ Model: ASYG36KMTA 1,330 Indoor temperature °CDB °CWB °CDB 7.77 6.96 1.06 8.05 6.98 1.08 8.23 7.00 1.10 8.69 7.33 1.12 9.14 7.50...
  • Page 12: Heating Capacity

    12.69 3.43 12.60 3.43 12.31 3.44 11.50 3.45 13.37 3.44 13.31 3.44 13.21 3.44 12.91 3.45 12.06 3.46 ¢ Model: ASYG36KMTA 1,330 Indoor temperature °CDB °CWB 6.82 2.75 6.80 2.75 6.74 2.75 6.59 2.76 6.16 2.77 7.81 2.97 7.78 2.97 7.72...
  • Page 13: Fan Performance

    5. Fan performance 5-1. Air velocity distributions ¢ Models: ASYG30KMTA and ASYG36KMTA Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Unit: m/s Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Left &...
  • Page 14: Airflow

    5-2. Airflow ¢ Models: ASYG30KMTA and ASYG36KMTA  Cooling Fan speed Airflow 1,330 HIGH 1,100 QUIET  Heating Fan speed Airflow 1,330 HIGH 1,100 QUIET - 10 - 5-2. Airflow 5. Fan performance...
  • Page 15: Operation Noise (Sound Pressure)

    NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000 2,000 4,000 8,000 Octave band center frequency, Hz Octave band center frequency, Hz ¢ Model: ASYG36KMTA  Cooling  Heating NC-65 NC-65 NC-60 NC-60 HIGH HIGH NC-55 NC-55 NC-50 NC-50 NC-45...
  • Page 16: Sound Level Check Point

    6-2. Sound level check point Microphone Microphone NOTE: Detailed shape of the actual indoor unit might be slightly different from the one illustrated above. - 12 - 6-2. Sound level check point 6. Operation noise (sound pressure)
  • Page 17: Safety Devices

    7. Safety devices Model Type of Protection form protection ASYG30KMTA, ASYG36KMTA Circuit Current fuse (PCB*) 250 V, 3.15 A protection 125±25 °C Activate Fan motor stop Thermistor protection °C Reset Fan motor Fan motor restart protection 150±15 °C Activate Power IC thermal...
  • Page 18: External Input And Output

    8. External input and output External input and output PCB SW301 SW302 Rotary switch CN314 CN313 CN312 CN311 CN310 CN308 To CN6 on Indoor unit PCB External input External output Connector Input select Input signal Operation/Stop CN313/ Edge/Pulse Dry contact/ CN314 Forced stop —...
  • Page 19: External Input

    8-1. External input With using external input function, some functions on this product can be controlled from an external device. • “Operation/Stop” mode or "Forced stop" mode can be selected with function setting of indoor unit. • A twisted pair cable should be used. Maximum length of cable is 150 m. •...
  • Page 20: External Output

    8-2. External output Use an external output cable with appropriate external dimension, depending on the number of ca- bles to be installed. ¢ External input and output PCB • A twisted pair cable (22AWG) should be used. Maximum length of cable is 25 m. •...
  • Page 21: Combination Of External Input And Output

    8-3. Combination of external input and output By combining the function setting of the indoor unit and rotary switch setting of the External input and output PCB, you can select various combinations of functions. Combination examples of external input and output are as follows: External input External input Mode...
  • Page 22: Details Of Function

    8-4. Details of function ¢ Control input function • When function setting is “Operation/Stop” mode 1 – In the case of “Edge” input: Function Rotary SW on External External input Input signal Command setting input and output PCB Off → On Operation External input and 46-00...
  • Page 23 • When function setting is “Forced stop” mode – In the case of “Edge” input: Function Rotary SW on External External input Input signal Command setting input and output PCB Off → On Forced stop External input and 46-02 CN313 output PCB On →...
  • Page 24 • When function setting is “Operation/Stop” mode 2 – In the case of “Edge” input: Function Rotary SW on External External input Input signal Command setting input and output PCB Off → On Operation External input and 46-03 CN313 Stop (R.C. output PCB On →...
  • Page 25 • Forced thermostat off function Rotary SW on External External input Input signal Command input and output PCB Off → On Thermostat off External input and output PCB CN313 On → Off Normal operation Input Compressor Room temp. Set temp. - 21 - 8-4.
  • Page 26 ¢ Control output function • Operation/Stop status Rotary SW on External Output External output Command input and output PCB signal Off → On Operation External input and output PCB CN310 On → Off Stop The output is low when the unit is stopped. Operation Indoor unit Stop...
  • Page 27: Group Connection

    9. Group connection NOTE: Group control cannot be used together with Wireless LAN adapter. Installation procedure for group control system: A number of indoor units can be operated at the same time using a single remote controller. NOTE: When different type of indoor units (such as wall mounted type and cassette type, cassette type and duct type, or other combinations) are connected using group control system, some functions may no longer be available.
  • Page 28: Remote Controller

    10. Remote controller 10-1. Wireless remote controller ¢ Overview Signal SENSOR button transmitter MODE button FAN button 10°C HEAT button SWING button ECONOMY button TEMP. button OUTDOOR UNIT SET button LOW NOISE button POWERFUL button WEEKLY button TIMER SETTING button Start/Stop button ON/OFF button...
  • Page 29 ¢ Specifications  Controller Unit: mm Top view Front view Side view Size (H × W × D) 205 × 61 × 17 Weight 124 (without batteries)  Holder Unit: mm 48.5 Ø 3.5 (Hole) Hole 26.2 69.3 Front View Side View Bottom View Size (H ×...
  • Page 30: Function Settings

    11. Function settings To adjust the functions of this product according to the installation environment, various types of function settings are available. NOTE: Incorrect settings can cause a product malfunction. 11-1. Function settings by using remote controller Some function settings can be changed on the remote controller. After confirming the setting proce- dure and the content of each function setting, select appropriate functions for your installation envi- ronment.
  • Page 31 NOTES: • The air conditioner custom code is set to prior to shipment. • If you do not know the air conditioner custom code setting, try each of the custom codes ( → → → ) until you find the code that operates the air conditioner. ¢...
  • Page 32 2) Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room. If the indication is not required, select "No indication" (03). Function number Setting value Setting description Factory setting...
  • Page 33 4) Room temperature control for wired remote controller sensor Depending on the installed environment, correction of the wire remote temperature sensor may be required. Select the appropriate control setting according to the installed environment. To change this setting, set Function 42 to Both “01”. Ensure that the Thermo Sensor icon is displayed on the remote controller screen.
  • Page 34 7) Remote controller custom code (Only for wireless remote controller) The indoor unit custom code can be changed. Select the appropriate custom code. Function number Setting value Setting description Factory setting ♦ 8) External input control "Operation/Stop" mode or "Forced stop" mode can be selected. Function number Setting value Setting description...
  • Page 35: 11-2.Custom Code Setting For Wireless Remote Controller

    11-2. Custom code setting for wireless remote controller To interconnect the air conditioner and the wireless remote controller, assignment of the custom code for the wireless remote controller is required. NOTE: Air conditioner cannot receive a signal if the air conditioner has not been set for the custom code.
  • Page 36: Accessories

    12. Accessories Part name Exterior Q’ty Part name Exterior Q’ty Operating manual Drain hose insulation Installation manual Cloth tape Wall hook bracket Tapping screw (large) Remote controller Tapping screw (small) Battery Air cleaning filters Remote controller Filter holder holder - 32 - 12.
  • Page 37: Optional Parts

    13. Optional parts 13-1. Controllers Exterior Part name Model name Summary Easy finger touch operation with LCD panel. Backlit LCD enables easy operation in a dark room. Wired remote UTY-RNRYZ* Wire type: Non-polar 2-wire controller Optional communication kit is necessary for installation. High visibility and easy operation.
  • Page 38: 13-2.Others

    13-2. Others Exterior Part name Model name Summary Required when external device is External connected. UTY-XWZXZ5 connect kit Use to connect with external devices External input and air conditioner PCB. UTY-XCSXZ2 and output PCB Optional External connect kit is necessary for installation. Communication Use to connect Non-polar 2-core wired UTY-TWRXZ2...
  • Page 39: Part 2. Outdoor Unit

    Part 2. OUTDOOR UNIT SINGLE TYPE: AOYG30KMTA AOYG36KMTA...
  • Page 40: Specifications

    1. Specifications Type Inverter heat pump Model name AOYG30KMTA AOYG36KMTA Power supply 230 V ~ 50 Hz Power supply intake Outdoor unit Available voltage range 198—264 V Starting current 10.2 13.9 Cooling 3,750 Airflow rate Heating 3,750 Type × Q'ty Propeller ×...
  • Page 41: Dimensions

    2. Dimensions 2-1. Models: AOYG30KMTA and AOYG36KMTA Unit: mm 35.7 Top view 3 Way valve (Liquid) 3 Way valve (Gas) Pipe port 25 67 Ф28: Cable port Ф28: Cable port Ф28: Cable port Ф28: Cable port Ф28: Cable port Ф28: Cable port Pipe port Pipe port Front view...
  • Page 42: Installation Space

    3. Installation space 3-1. Models: AOYG30KMTA and AOYG36KMTA ¢ Space requirement Provide sufficient installation space for product safety.  Single outdoor unit installation • When the upper space is open: Unit: mm When there are obstacles at the rear only. When there are obstacles at the rear and sides.
  • Page 43  Multiple outdoor unit installation • When the upper space is open: Unit: mm When there are obstacles at the rear only. When there are obstacles at the front only. 1,500 or more 250 or more or more When there are obstacles at the front and rear.
  • Page 44  Outdoor unit installation in multi-row Unit: mm Single parallel unit arrangement Multiple parallel unit arrangement 150 or more 500 or more 3,000 or more 3,500 or more 600 or more 600 or more 1,500 or more 1,500 or more 250 or more 1,500 or more 500 or more...
  • Page 45: Refrigerant Circuit

    4. Refrigerant circuit 4-1. Models: AOYG30KMTA and AOYG36KMTA Heat exchanger 3-Way ( INDOOR ) valve 2-Way valve Pressure switch 4-Way valve Strainer Expansion valve Heat exchanger Strainer ( OUTDOOR ) : Cooling : Heating : Thermistor (Compressor temperature) : Thermistor (Discharge temperature) : Thermistor (Heat Exchanger Med temperature) : Thermistor (Outdoor temperature) : Thermistor (Heat Exchanger Out temperature)
  • Page 46: Wiring Diagrams

    5. Wiring diagrams 5-1. Models: AOYG30KMTA and AOYG36KMTA - 42 - 5-1. Models: AOYG30KMTA and AOYG36KMTA 5. Wiring diagrams...
  • Page 47: Capacity Compensation Rate For Pipe Length And Height Difference

    6. Capacity compensation rate for pipe length and height difference Height difference H Indoor unit is higher than outdoor unit Indoor unit is lower than outdoor unit Outdoor unit Indoor unit Outdoor unit Indoor unit Connection pipe Connection pipe 6-1. Model: AOYG30KMTA NOTE: Values mentioned in the table are calculated based on the maximum capacity.
  • Page 48: Model: Aoyg36Kmta

    6-2. Model: AOYG36KMTA NOTE: Values mentioned in the table are calculated based on the maximum capacity. Pipe length (m) COOLING — — — — 0.902 0.882 0.862 — — — 0.938 0.917 0.897 0.876 Indoor unit is higher — — 0.973 0.953 0.933...
  • Page 49: Additional Charge Calculation

    7. Additional charge calculation 7-1. Models: AOYG30KMTA and AOYG36KMTA Refrigerant type Refrigerant amount 1,900 ¢ Refrigerant charge Total pipe length 30 or less 50 (Max.) 40 g/m Additional charge amount - 45 - 7-1. Models: AOYG30KMTA and AOYG36KMTA 7. Additional charge calculation...
  • Page 50: Airflow

    8. Airflow 8-1. Models: AOYG30KMTA and AOYG36KMTA  Cooling 3,750 1,042 2,207  Heating 3,750 1,042 2,207 - 46 - 8-1. Models: AOYG30KMTA and AOYG36KMTA 8. Airflow...
  • Page 51: Operation Noise (Sound Pressure)

    9. Operation noise (sound pressure) 9-1. Noise level curve ¢ Model: AOYG30KMTA  Cooling  Heating NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40 NC-35 NC-35 NC-30 NC-30 NC-25 NC-25 NC-20 NC-20 NC-15 NC-15 1,000 2,000 4,000 8,000 1,000...
  • Page 52: Sound Level Check Point

    9-2. Sound level check point Rear Microphone Microphone Airflow Side view Rear view NOTE: Detailed shape of the actual outdoor unit might be slightly different from the one illustrated above. - 48 - 9-2. Sound level check point 9. Operation noise (sound pressure)
  • Page 53: Electrical Characteristics

    10. Electrical characteristics Model name AOYG30KMTA AOYG36KMTA Voltage 230 ~ Power supply Frequency 21.0 21.5 Max operating current* Starting current 10.2 13.9 Circuit breaker current Power cable Wiring spec.* Connection Cross-sectional area cable* Limited wiring length *1: Maximum current is the total current of the indoor unit and the outdoor unit. *2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005.
  • Page 54: Safety Devices

    11. Safety devices Model Type of Protection form AOYG30KMTA protection AOYG36KMTA 250 V, 30 A Circuit Current fuse 250 V, 3.15 A protection (Main PCB) 250 V, 10 A × 2 122 ±9 °C Activate Fan motor stop Fan motor Thermal protection program protection 107—126 °C...
  • Page 55: External Input And Output

    12. External input and output With using external input and output functions, this product can be operated inter-connectedly with an external device. Connector Input Output Remarks P580 Low noise mode — PA580 Peak cut mode — See external input/output settings for details.
  • Page 56 ¢ Peak cut mode By performing following on-site work, operation that suppresses the current value can be enabled: The air conditioner is set to the “Peak cut mode” when closing the contact input of a commercial timer or on/off switch to a connector on the control PCB of the outdoor unit. •...
  • Page 57: 12-2.External Output

    12-2. External output With using external output function, some status signals are transmitted to the control PCB, and the related LED lamp indicates the status of this product. ¢ Error status output Signal on air conditioner error status is generated when a malfunction occurs. •...
  • Page 58 ¢ Compressor status output Signal on compressor operation status is generated when the compressor is running. • Circuit diagram example • Output voltage (Vcc): DC 12 V Outdoor unit 50 mA or less control PCB Connected unit (Locally purchased) • *: Make the distance from the Example: Connector Example: Fan...
  • Page 59: Function Settings

    13. Function settings Perform appropriate function setting locally according to the installation environment. NOTE: Incorrect settings can cause a product malfunction. CAUTION • Before setting up the switch buttons, discharge the static electricity from your body. • Never touch the terminals or the patterns on the parts that are mounted on the PCB. 13-1.
  • Page 60 ¢ Switch buttons and the functions LED lamps S134 S133 S132 S131 S130 Switch buttons LED lamp Function or operation method Lights on while power on. (1) POWER/MODE Green Local setting in outdoor unit or error code is displayed with blink. (2) ERROR Blinks during error operation.
  • Page 61: 13-2.Local Setting Procedure

    13-2. Local setting procedure NOTE: Before performing the function setting, be sure to stop the operation of the air conditioner. ¢ Low noise mode Press the MODE switch button (S134) for 3 seconds or more to switch to “Local setting mode”. After confirming the LED lamp of POWER/MODE blinks 9 times, press the ENTER switch but- ton (S132).
  • Page 62 ¢ Peak cut mode Press the MODE switch button (S134) for 3 seconds or more to switch to “Local setting mode”. After confirming the LED lamp of POWER/MODE blinks 9 times, press the ENTER switch but- ton (S132). PUMP POWER LOW NOISE PEAK CUT DOWN...
  • Page 63: Accessories

    14. Accessories 14-1. Models: AOYG30KMTA and AOYG36KMTA Part name Exterior Q’ty Part name Exterior Q’ty Installation manual Drain cap Drain pipe One-touch bush - 59 - 14-1. Models: AOYG30KMTA and AOYG36KMTA 14. Accessories...
  • Page 64: Optional Parts

    15. Optional parts Exterior Part name Model name Summary Use to operate the external input and External UTY-XWZXZ3 output functions of outdoor unit. connect kit - 60 - 15. Optional parts...