Trouble Shooting - Daitsu ADP 12AM Instruction Manual

Hide thumbs Also See for ADP 12AM:
Table of Contents

Advertisement

Available languages

Available languages

07ManPORTATILDaitsuEng
7/2/07
Troubles
Unit does not start
when pressing 1/0
button
Not cool enough
Power shut off at
heating mode
Noisy or vibration
Gurgling sound
40
10:13
Página 40

TROUBLE SHOOTING

Possible causes
Water full indicator blinks, water tank is full.
Room temperature is higher than the set tem-
perature.(Heating mode)
Room temperature is lower than the set tem-
perature.(Cooling mode)
The windows or doors in the room are not clo-
sed.
There are heat sources inside the room.
Exhaust air duct is not connected or blocked.
Temperature setting is too high.
Air filter is blocked by dust.
The automatic over heat protection function.
When the temperature at the air outlet exceed
70ºC/158ºF, the device willst op.
The ground is not level or not flat enough.
The sound comes from the flowing of the refri-
gerant inside the air-conditioner.
Suggest remedies
Dump the water in the water tank.
Reset the temperature.
Reset the temperature.
Make sure all the windows anddoors are clo-
sed.
Remove the heat sources if possible.
Connect the duct and makesure it can function
properly.
Decrease the set temperature.
Clean the air filter.
Switch on again after the unit has cool down.
Place the unit on a flat, levelground if possible.
It is normal.