1. Application Object
These instructions apply to the RF-04FA(MN/MW-71PY10
Monitor) Chassis.
2. Specification
(1) Because this is not a hot chassis, it is not necessary to
use an isolation transformer. However, the use of isolation
transformer will help protect test equipment.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25±5°C of temperature and 65±10% of relative humidity.
(4) The input voltage of the receiver must keep 100~220V,
50/60Hz.
(5) The receiver must be operated for about 15 minutes prior
to the adjustment.
After RGB Full white HEAT-RUN Mode, the receiver must
O
be returned to normal operation prior to adjustment.
Enter into HEAT-RUN MODE
O
1) Press the POWER ON KEY on R/C for adjustment.
2) OSD display and screen display 100% full WHITE
PATTERN.
[ Set is activated HEAT-RUN without a signal generator in
this mode.
[ Single color pattern(RED/BLUE/GREEN) of HEAT-RUN
mode is used to test the PANEL.
Caution) If you turn on a still screen more than 20 minutes
(Especially digital pattern, cross hatch pattern), an
afterimage may be occur in the black level part of the
screen.
3. HDCP Download
3-1. LGIDS Setting Method
(1) Click on 'setup' to install in your directory.
(2) After installation has completed, check if the file shown on
(Fig. 4) has been created.
(3) Copy the KEY from source CD into the HDCP directory
which was installed just now.
(DVI_orderNo_2003_data)
(4) After running HDCP(application program) which is inside
the HDCP directory, setup the Communication.
Port : COM1(modification possible)
BaudRate : 115200

ADJUSTMENT INSTRUCTIONS

3-2. KEY Generation
(1) Click on 'Key Generation (G)'.
(2) Input the quantity of keys to be generated.
ex) If 100 Keys are required, then just register 100 and
next time it will automatically get 101.
(3) Input file : When installing the program for the first time,
you must find the original KEY that you copied and open it.
It is crucial that you copy the original KEY into this
directory.
When you use Generation, the information is recorded in
Config.ini.
- 9 -
(Fig. 1)
(Fig. 2)

Advertisement

loading

This manual is also suitable for:

Mw-71py10g