General Instructions On Property Damage And Product Damage - Bosch Rexroth A10VOH145 60 Series Instruction Manual

Axial piston variable pump
Table of Contents

Advertisement

14/56
A10VOH145 series 60 | General instructions on property damage and product damage
Bosch Rexroth AG, RE 92704-01-B/2022-12-07
3 General instructions on property
damage and product damage
The following notices apply to chapters 6 to 14.
Danger from improper handling!
Product can be damaged!
▶ Do not subject the product to improper mechanical loads.
▶ Never use the product as handle or step.
▶ Do not put/place any objects on the product.
▶ Do not strike the drive shaft of the axial piston unit.
▶ Do not set/place the axial piston unit on the drive shaft or assembled parts.
▶ Do not strike assembled parts (e.g. sensors. solenoids or valves).
▶ Do not hit sealing surfaces (e.g. on the working ports).
▶ Leave the protective covers on the axial piston unit until you connect the lines.
▶ Disconnect all electrical connectors before arc welding and painting
operations.
▶ Make sure the electronic components (e.g. sensors) do not build up
electrostatic charges (e.g. during painting operations).
Risk of property damage due to inadequate lubrication!
Product can be damaged or destroyed!
▶ Never operate the axial piston unit with insufficient hydraulic fluid.
Specifically, make sure that the rotary group has sufficient lubrication.
▶ When commissioning a machine/system, make sure that the housing area and
the working lines of the axial piston unit are filled with hydraulic fluid and
remain filled during operation.
▶ Check the hydraulic fluid level in the housing area regularly and replenish,
if necessary. For above-reservoir installation, the housing area may drain out
through the drain line after prolonged standstill periods (air enters through
the shaft seal) or through the working line (gap leakage). This means the
bearings are insufficiently lubricated when the system is turned on.
▶ Make sure the suction line is always filled with hydraulic fluid during
commissioning and operation.
▶ Ensure in case of above-reservoir installation that before initial start-up of the
axial piston pump (commissioning or recommissioning), the suction line is
completely filled with hydraulic fluid. Make certain that the axial piston pump
does suck in hydraulic fluid and build up pressure directly after start-up.
In case of longer standstill, suitable measures have to be taken to prevent
draining of the suction line.