A10VOH145 series 60 | Installation
Table 9: Tightening torques for female threads and threaded plugs
Ports
Standard
Thread size
ISO 11926
5/16-24 UNF-2B
3/8-24 UNF-2B
7/16-20 UNF-2B
9/16-18 UNF-2B
3/4-16 UNF-2B
7/8-14 UNF-2B
1 1/16-12 UN-2B
1 5/16-12 UN-2B
1 5/8-12 UN-2B
1 7/8-12 UN-2B
Procedure
Bosch Rexroth AG, RE 92704-01-B/2022-12-07
In addition to the ports specified in Table 8 "Ports A10VOH145 series 60"
on page 37, axial piston units may have openings that are also closed with
a threaded plug. These plugs must not be opened on the customer side.
If you have opened the threaded plug accidentally, please contact your local
contact person to ensure safe re-closing of the plug. You can find the address at
https://addresses.boschrexroth.com
Maximum permissible
tightening torque of
female threads M
G max
10 Nm
20 Nm
40 Nm
80 Nm
160 Nm
240 Nm
360 Nm
540 Nm
960 Nm
1200 Nm
To connect the axial piston unit to the hydraulic system:
1� Remove the protective plugs and/or threaded plugs from the ports where the
connections should be made according to the hydraulic circuit diagram.
2� Make sure the sealing surfaces of the hydraulic ports and functional surfaces
are not damaged.
3� Use only clean hydraulic lines or flush them before installation.
(Observe chapter 7.5 "Performing flushing cycle" on page 40 when you flush
the hydraulic system.)
4� Connect the lines in accordance with the installation drawing and the machine
or system circuit diagram. Check that all ports are connected or plugged
with threaded plugs. For inside-reservoir installation, the housing of the
axial piston unit must be filled before fitting the lines and filling the reservoir
with hydraulic fluid.
5� Properly tighten the fittings (observe tightening torques!).
Mark all properly tightened fittings, e.g. with a permanent marker.
6� Check all pipes and hose lines and every combination of connecting pieces,
couplings or connecting points with hoses or pipes to ensure they are in safe
working condition.
Required tightening torque
of threaded plugs M
V
7 Nm
10 Nm
18 Nm
35 Nm
70 Nm
110 Nm
170 Nm
270 Nm
320 Nm
390 Nm
WAF hexagon socket of the
threaded plug
1/8 in
5/32 in
3/16 in
1/4 in
5/16 in
3/8 in
9/16 in
5/8 in
3/4 in
3/4 in