KERN PCD Series Operating Instructions Manual

KERN PCD Series Operating Instructions Manual

Precision balance
Hide thumbs Also See for PCD Series:

Advertisement

Quick Links

Operating instructions
Precision balance
KERN PCD
Version 1.5
09/2016
GB
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-mail:info@kern-sohn.com
Phone: +49-[0]7433- 9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
PCD-BA-e-1615

Advertisement

Table of Contents
loading

Summary of Contents for KERN PCD Series

  • Page 1 KERN & Sohn GmbH Ziegelei 1 Phone: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-mail:info@kern-sohn.com Internet: www.kern-sohn.com Operating instructions Precision balance KERN PCD Version 1.5 09/2016 PCD-BA-e-1615...
  • Page 2: Table Of Contents

    KERN PCD Version 1.5 09/2016 Operating instructions Precision balance Contents Technical data ....................4 Basic Information (General) ................7 Proper use ..........................7 Improper Use ..........................7 Warranty ............................. 7 Monitoring of Test Resources ..................... 7 Basic Safety Precautions ................8 Pay attention to the instructions in the Operation Manual ............
  • Page 3 Menu ......................25 Navigation in the menu ......................25 Menu overview .......................... 28 Description of individual menu items ..................30 8.3.1 Weighing Units ......................... 30 8.3.2 Dosing and Zero-tracking ......................31 8.3.3 Selection of adjustment weight ....................32 8.3.4 Filterfunction ..........................33 8.3.5 Display background illumination ....................
  • Page 4: Technical Data

    Technical data KERN PCD 250-3 PCD 300-3 Readability (d) 0.001 g 0.001 g Weighing range (max) 250 g 350 g Taring range (subtractive) 250 g 350 g Reproducibility 0.002 g 0.002 g Linearity ±0.005 g ±0.005 g Minimum unit weight at 0.002 g...
  • Page 5 KERN PCD 2500-2 PCD 3000-2 Readability (d) 0.01 g 0.01 g Weighing range (max) 2500 g 3.5 kg Taring range (subtractive) 2500 g 3.5kg Reproducibility 0.02 g 0.02 g Linearity ±0.05 g ±0.05 g Minimum unit weight at 0.02 g 0.02 g...
  • Page 6 KERN PCD 6K-4 PCD 10K0.1 PCD 10K3 Readability (d) 0.1 g 0.1 g Weighing range (max) 6000 g 10 kg 10 kg Taring range (subtractive) 6000 g 10 kg 10 kg Reproducibility 0.1 g 0.1 g Linearity ±0.3 g ±0.3 g ±3 g...
  • Page 7: Basic Information (General)

    Information is available on KERN’s home page (www.kern-sohn.com) with regard to the monitoring of balance test substances and the test weights required for this. In KERN’s accredited DKD calibration laboratory test weights and balances may be calibrated (return to the national standard) fast and at moderate cost.
  • Page 8: Basic Safety Precautions

    3 Basic Safety Precautions 3.1 Pay attention to the instructions in the Operation Manual Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances. 3.2 Personnel training The appliance may only be operated and maintained by trained personnel.
  • Page 9: Unpacking, Setup And Commissioning

    5 Unpacking, Setup and Commissioning 5.1 Installation Site, Location of Use The balances are designed in a way that reliable weighing results are achieved in common conditions of use. You will work accurately and fast, if you select the right location for your balance. On the installation site observe the following: •...
  • Page 10 Mount the display unit in a way that facilitates operation and where it is easy to see. 1. Display unit assembled For disassembly remove the assembly sheet by loosening the marked screws. After that the display unit can be placed freely. 2.
  • Page 11 3. Using with tripod (optional) In order to raise the display, the display unit can be assembled to an optionally available tripod (KERN PCD-A03). Assembly see installation instructions of the tripod. The balance must be installed in a way that the weighing plate is exactly in horizontal position.
  • Page 12: Mains Connection

    5.3 Mains connection Power is supplied via the external mains adapter. The stated voltage value must be the same as the local voltage. Only use original KERN mains adapters. Using other makes requires consent by KERN. 5.4 Operation using a rechargeable battery (optional) Lift-off the battery cover on the lower side of the balance.
  • Page 13: Connection Of Peripheral Devices

    Before connecting or disconnecting of additional devices (printer, PC) to the data interface, always disconnect the balance from the power supply. With your balance, only use accessories and peripheral devices by KERN, as they are ideally tuned to your balance.
  • Page 14: Linearisation

    5.7 Linearisation (only models PCD 250-3, PCD 2500-2) Linearity shows the greatest deviation of a weight display on the scale to the value of the respective test weight according to plus and minus over the entire weighing range. If linearity deviation is discovered during a monitoring of test resources, you can improve this by means of linearization.
  • Page 15  Press repeatedly until LinEAr is displayed  Ensure that there are no objects on the weighing pan.  Start linearisation with . The value of the first adjustment weight will be displayed. (example)  Place adjustment weight and acknowledge by .
  • Page 16: Adjustment

     Place fifth adjustment weight and acknowledge . The scales will change to zero display.  Take away adjustment weight. After a short time CAL F is displayed. Finally the balance will switch off automatically. Now the linearization is concluded successfully.
  • Page 17: Adjustment

    5.9 Adjustment The adjustment should be made with the recommended adjustment weight (see chap. 1 "Technical data"). Adjustment is also possible with the weights of other nominal values (see table 1), but not the optimum for measuring technique. Procedure when adjusting: Observe stable environmental conditions.
  • Page 18: Operating Elements

    6 Operating elements 6.1 Overview of display 6.2 Keyboard overview Description Function • Calculate weighing data via interface PRINT button • Call up menu (keep key pressed until UNIT appears) • Confirm settings in the menu SET button • Save and exit menu •...
  • Page 19: Basic Operation

    7 Basic Operation 7.1 Start-up  Press ON button. O F F The balance will carry out a self-test As soon as the weight display appears, the balance is ready for weighing. 7.2 Switching Off  Press OFF button, the display disappears O F F 7.3 Weighing ...
  • Page 20: Taring

    7.4 Taring  Place an empty weighing container, the weight of the weighing container will be displayed.  Press the TARE button, the zero display disappears. TA R E The tare weight is saved until it is deleted.  Weigh the material, the net weight will be indicated. The taring process can be repeated any number of times, e.g.
  • Page 21: Pre-Tare Function

    7.5 Pre-Tare function Using this function the weight of a tare vessel is stored. Even M O D E after turning off/on the weighing balance will continue working C A L with the saved tare value.  In weighing mode put tare vessel on the weighing plate ...
  • Page 22: Parts Counting

    7.7 Parts counting During piece counting parts can either be counted into a container or out of a container. To count a greater number of parts the average weight per part has to be determined with a small quantity (reference quantity). The larger the reference quantity, the higher the counting exactness.
  • Page 23: Net-Total Weighing

    7.8 Net-total weighing It is useful if a mixture of several components is weighed into a tare vessel and finally the sum weight of all weighed components is necessary for control purposes (net-total, i.e. the weight of the tare vessel). Example: 1.
  • Page 24: Percent Determination

    7.9 Percent determination Percentage calculation facilitates weight display in percent related to a reference weight equivalent to 100 %.  In weighing mode press MODE key repeatedly, M O D E until “100 %“ is displayed flashing. C A L ...
  • Page 25: Menu

    8 Menu 8.1 Navigation in the menu Access to menu P R IN T In weighing mode keep the PRINT key pressed until „Unit“ appears. How to select menu items Using the MODE key the individual menu M O D E C A L items can be selected one after the other.
  • Page 26 2. Change settings of several menu items S E T Acknowledge selected menu item using SET key, the current setting is displayed. Use the MODE key to change settings. M O D E C A L TA R E Press the TARE key, „Exit“ is displayed. Either S E T Acknowledge with SET key (yes),...
  • Page 27 Save/reject and exit the menu S E T  Save Either S E T Any changes carried out are stored by pressing the SET key (yes). The balance returns automatically into weighing mode.  Reject P R IN T To cancel changes, press the PRINT key (no).
  • Page 28: Menu Overview

    8.2 Menu overview Description of function Function Parameter Description of options UNIT Gram Weighing units switching Pound over (see chap. 8.3.1) Ounce Carat (dependent on model) Tael Hongkong Tael Taiwan Grain (dependent on model) Pennyweight (dependent model) Momme Tola Freely selectable factor Data transfer mode (see Data output via remote control rE CR*...
  • Page 29 Baud rate bAUd 19200 (see chap. 8.4.4) 9600* 4800 2400 1200 Automatic switch-off function after Auto off 3 min without changing load ON (battery operation), see (chap. 5.4) Automatic switch-off function after 3 min without changing load OFF Auto Zero (see chapter 8.3.2) Selection adjustment *dependent on model...
  • Page 30: Description Of Individual Menu Items

    8.3 Description of individual menu items 8.3.1 Weighing Units  In weighing mode keep the PRINT key pressed until [Unit] appears.  Press SET key, the selected unit is displayed.  Use the MODE key to select between the different units (see following table).
  • Page 31: Dosing And Zero-Tracking

    8.3.2 Dosing and Zero-tracking The Auto-Zero function is used to tare small variations in weight automatically. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the “stability compensation“. (Example: Slowly draining fluids from a container on the balance).
  • Page 32: Selection Of Adjustment Weight

    8.3.3 Selection of adjustment weight In the model series KERN PCD, the adjustment weight can be selected from pre-set nominal values (refer also to following table, factory setting with grey background). In order to achieve high- quality weighing results in the sense of the measuring technology, it is recommended to select the nominal value as high as possible.
  • Page 33: Filterfunction

    8.3.4 Filterfunction (except PCD 10K-3) This menu item allows the balance to be set according to specific ambient conditions and measuring purposes.  In weighing mode keep the PRINT key pressed until [Unit] appears.  Press the MODE button several times until „StAbiL“ is displayed.
  • Page 34: Display Background Illumination

    8.3.5 Display background illumination  In weighing mode keep the PRINT key pressed until “Unit“ appears.  Press the MODE button several times until „bl“ is displayed.  Acknowledge using SET key, the current setting is displayed.  Select the desired settings by pressing the MODE key. Background illumination Contrastful display which can bl on...
  • Page 35: Animal Weighing Function

    8.3.6 Animal weighing function The animal weighing function can be applied for busy weighings. During a defined period the mean value of the weighing results is formed. The more unquiet the weighed item, the longer the period should be selected. ...
  • Page 36: Foot Switch

    8.3.7 Foot switch The foot switch is used to send the weighing values to a printer or to a PC. Alternatively can also be tared. Connection and operation see in the operating instructions supplied with this foot switch. 8.3.8 Reset to factory setting This function resets all balance settings to factory setting.
  • Page 37: Interface Parameters

    8.4 Interface parameters Data output is carried out via interface RS 232 C. General The previous condition for the data transfer between balance and a periphericall device (e.g. printer, PC ...) is that the appliances are set to the same interface parameters (e.g.
  • Page 38: Printout

    8.4.2 Printout Using this function data are selected which are to be sent via the RS232C (not valid for data transfer mode BAPr ).  In weighing mode keep the PRINT key pressed until “Unit“ appears.  Press the MODE key several times until „LAPr“ is displayed. ...
  • Page 39: Printout Example

    8.4.3 Printout example Page forward feed when started line1 Edition of the headlines line 2 line 3 line 4 line 5 135.81 g Total weight 28.27 g Net weight 1.49 g Tare weight 12.25 g Saved weight 5 pcs Quantity 5.63 g Piece weight 2 pcs Reference quantity Page forward feed when ended...
  • Page 40: Data Output Rs 232 C

    • Baud rate selectable at 1200, 2400, 4800, 9600 and 19200 Baud • Miniature plug-in necessary (9 pole D-Sub) • For operation with interface faultless operation is only ensured with the correct KERN – interface cable (max. 2m) 9.2 Pin allocation of balance output bushing: Front view:...
  • Page 41: Explanation Of The Data Transfer

    9.3 Explanation of the data transfer Pr PC Press the PRINT key, at stable weight the format is transferred from LAPR. a. Format for stable values for weight/quantity/percentage CR LF b. Format in case of fault 10 11 12 13 14 15 16 17 AU Pr: As soon as the weighing value is stable, the format is automatically transferred from LAPR.
  • Page 42 rE Cr: The remote control commands s/w/t are sent from the remote control unit to the balance as ASCII code. After the balance having received the s/w/t commands, it will send the following data. Take into account that the following remote control commands must be sent without a subsequent CR LF.
  • Page 43: Output On Bar Code Printer

    The printer format is stored in the printer, i.e. in case of a failure the printer cannot be changed with a new one from factory, previously it is necessary that KERN installs the respective software. The Zebra printer and the balance must be connected to the delivered interface cable when they are switched off.
  • Page 44: Service, Maintenance, Disposal

     Do not use metal brushes or cleaning sponges of steel wool, as this causes superficial corrosion. 10.2 Service, maintenance  The appliance may only be opened by trained service technicians who are authorized by KERN.  Ensure that the balance is regularly calibrated, see chap. Testing instruments control. 10.3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used.
  • Page 45: Instant Help

    11 Instant help In case of an error in the program process, briefly turn off the balance and disconnect from power supply. The weighing process must then be restarted from the beginning. Help: Fault Possible cause • The balance is not switched on. The displayed weight does not glow.
  • Page 46: Declaration Of -Conformity

    12 Declaration of -Conformity To view the current EC/EU Declaration of Conformity go to: www.kern-sohn.com/ce PCD-BA-e-1615...

Table of Contents