TROUBLESHOOTING

If you experience any faults, please check the Troubleshooting section below. If a problem cannot be remedied or you are
experiencing difficulty in installation, please contact Customer Service: 1-877-361-3883, Monday-Friday, 8am - 5pm, Central Time.
WARNING: Shut off the power supply before you begin any maintenance task.
PROBLEM
The fan does not
move.
The fan is noisy.
The fan wobbles
excessively.
The fan operates
correctly but the lights
.
are not working
Remote does not
work.
1. Firmly push the reverse switch completely left or right.
2. Make sure the wall switch is turned on.
3. Turn the power on or check the fuse (breaker).
4. Turn the power off and check all connections at the ceiling outlet box.
1. Check and tighten all screws that hold the fan blades to the blade arms and the motor.
2. Replace the cracked blade.
3. Do not use a full range dimmer switch to control the fan speed.
4. Ensure the outlet box is secured to the building structure.
5. Ensure the mounting bracket is secured to the outlet box and that the screws are tight.
1. Check and tighten all screws that hold the fan blades to the blade arms and the blade arms to the
motor.
2. Switch one blade with a blade from the opposite side, or balance the fan using the blade
balancing kit.
3. Turn off the power. Loosen the canopy and verify that the mounting bracket is secure to the
electrical outlet box. The bracket must be flush without movement against the outlet box. Verify
the outlet box is secure.
4. Use a longer downrod (sold separately) or move the fan to another location.
5. Lift up the yoke cover and tighten the set screws on the yoke until secure.
1. Ensure the Single-pin connectors are properly secured.
2. Turn the power off and check all connections at the ceiling outlet box.
1. Power surge may have cleared the memory and remote needs to be resynced to the receiver.
Syncing instructions: Turn off the power at the breaker box for at least 10 seconds and then turn
the power back on. Within 30 seconds, press and hold the "LEARN" button (Figure 6.1) on the back
of the remote for 3 seconds. The fan will turn on at high speed and light will blink twice and stay on,
signaling a successful synchronization.
2. Insert new CR2032 batteries in battery compartment of the wall control.
3. If there are several remote fans in proximity, turn the power off to those fans and re-sync the fan.
CORRECTIVE ACTION