Power Connections To Hydraulic Motor - Maxwell HWVC3500 Series Manual

Horizontal windlass
Table of Contents

Advertisement

Seal" or equivalent.
Total Cable Length From
Battery to Winch Then Back
to Battery
Up to 10m (33')
10m - 15m (33'-50')
15m – 20m (50' – 65')
20m – 25m (65' – 82')
25m – 35m (82' – 115')
35m – 45m (115' – 150')
Total Cable Length From
Battery to Winch Then Back
to Battery
Up to 10m (33')
10m - 15m (33'-50')
15m – 20m (50' – 65')
20m – 25m (65' – 82')
2.6
POWER CONNECTION TO HYDRAULIC MOTORS
A basic hydraulic schematic is shown in Appendix C.
Port sizes on the hydraulic motor and minimum hose
sizes are specified in Section 1.3.
The motor has pressure and return ports. The
pressure and return ports should be connected to a
solenoid controlled valve (not supplied by Maxwell).
After connecting the power lines, spray all ports and
fittings with anti-corrosive waterproof coating, "CRC
3013 Soft Seal" or equivalent.
2.7
INSTALLATION OF CONTROLS
12v systems (135amp breaker)
Cable Size
mm²
AWG
25
4
35
2
50
1
50
0
70
2/0
95
3/0
24v systems (80amp breaker)
Cable Size
mm²
AWG
10
6
16
4
25
4
35
3
Table 2.1
Recommended wire sizes
Engine room Size Correction*
mm²
AWG
35
-
-
-
-
-
Engine room Size Correction*
mm²
AWG
6
42
2
-
-
-
-
-
5
1

Advertisement

Table of Contents
loading

Table of Contents