Chapter 2
DAQ System Overview
You can use one BNC accessory on connector 0 of any X Series device. An additional BNC
accessory may be used on connector 1 of any X series device except the NI 6345/6349/6355/
6365/6375 devices. The BNC-2115 can only be used on connectors 1, 2, or 3 of the NI 6345/
6355/6365/6375 devices and connector 1 of the NI 6349 device.

Screw Terminal Accessories

National Instruments offers several styles of screw terminal connector blocks. All terminal
connector blocks require a cable except the TB-2706 to connect an X Series device to a
connector block, as listed in Table 2-2.
Screw Terminal Accessory
CB-68LP and CB-68LPR
SCB-68A
TB-2706
*
TB-2706 (not for use with NI 6345/6346/6349/6355/6365/6375 devices) uses Connector 0 of your
PXI Express device. After a TB-2706 is installed, Connector 1 cannot be used.

RTSI Cables

Use RTSI bus cables to connect timing and synchronization signals among PCI/PCI Express
devices, such as X Series, M Series, CAN, and other measurement, vision, and motion devices.
Since PXI devices use PXI backplane signals for timing and synchronization, no cables are
required.

Cables

You can use the following cables:
2-6 | ni.com
Table 2-2. Screw Terminal Accessories
SCC-68
SCB-68
TBX-68
*
Description
Unshielded connector blocks
I/O connector block with screw terminals,
general breadboard area, bus terminals, and
four expansion slots for SCC signal
conditioning modules.
Shielded connector block with temperature
sensor
Screw terminal block with temperature
sensor
DIN rail-mountable connector block
Front panel mounted terminal block for
PXI Express X Series devices