Chapter 7
Counters

Routing Signals to Counter n HW Arm Input

Any of the following signals can be routed to the Counter n HW Arm input:
RTSI <0..7>
PFI <0..15>
AI Reference Trigger (ai/ReferenceTrigger)
AI Start Trigger (ai/StartTrigger)
PXI_STAR
PXIe_DSTAR<A,B>
Analog Comparison Event
Change Detection Event
A counter's Internal Output can be routed to a different counter's HW Arm.
Some of these options may not be available in some driver software.

Counter n Sample Clock Signal

Use the Counter n Sample Clock (CtrnSampleClock) signal to perform sample clocked
acquisitions and generations.
You can specify an internal or external source for Counter n Sample Clock. You can also specify
whether the measurement sample begins on the rising edge or falling edge of Counter n Sample
Clock.
If the DAQ device receives a Counter n Sample Clock when the FIFO is full, it reports an
overflow error to the host software.

Using an Internal Source

To use Counter n Sample Clock with an internal source, specify the signal source and the
polarity of the signal. The source can be any of the following signals:
DI Sample Clock (di/SampleClock)
DO Sample Clock (do/SampleClock)
AI Sample Clock (ai/SampleClock)
AI Convert Clock (ai/ConvertClock)
AO Sample Clock (ao/SampleClock)
DI Change Detection output
Several other internal signals can be routed to Counter n Sample Clock through internal routes.
Refer to Device Routing in MAX in the NI-DAQmx Help or the LabVIEW Help for more
information.
7-40 | ni.com