OIL BURNER DESCRIPTION
To fit out our Delta performance Oil boiler we needed a really high
performance burner to give perfect combustion.
We opted to use the brand new technology of the ACV BM R 31,
BM R 51 y BM 101 burners.
Chamber plate (oil)
The chamber plate has 4 screws (M 8 x 20 mm) for the fixing of
the burner. It is protected from the radiation of the flame by an
insulation blanket.
SETTING OIL BURNER PARAMETERS
Burner
Output
Electrical power
Nozzle
Nozzle angle
Oil flow rate
Pump pressure
Flue gas index
Air flap setting
Combustion head setting
Flue pressure drop
Weight
Relay
High viltage transformer
Motor
BM R 31
BM R 51
240
A
mm
B
mm
270
C
mm
215
D
mm
280
E
mm
60 - 130
F
M 8
G mm
80
Ø
L
85
LK Ø
140 - 165
OIL BURNER CHARACTERISTICS
kW
W
gal/h
kg/h
bar
mbar
kg
BM 101
260
300
250
310
60 - 150
M 8
90
95
125 - 180
F25
F35
BM R 31
BM R 31
12 / 48
12 / 48
150
150
0,6
0,75
60°
60°
2,18
2,84
11,2
12,0
0,6
0,3
4,5
4,8
1
2 - 3
0,02 / 0,09
0,08 / 0,09
12
12
EN • 13
4 x Ø6.5 (M8)
Ø112
Ø28
53
53
53
53
F45
BM R 51
42 / 60
150
0,85
60° B
3,60
15,0
0,4
4,5
4 - 5
0,01 / 0,08
12
F55
BM 101
55 / 130
185
1,50
60° B
5,76
10,0
0,5
5,0
4 - 5
0,02 / 0,05
14
Photoelectric sell
Burner connector
Solenoid valve
Oil pump