Preparing the citric acid flushing solution ....................21 FLUSHING Mode ............................22 Connecting diagram of the EMERALD Device at the CIRCULATION and HOLD-UP stages ....24 Connecting diagram for EMERALD Device at the WASHING-OUT stage ..........25 TROUBLESHOOTING GUIDE ................... 26 WARRANTY ........................
Manual, the EMERALD Device will serve you for many years. 1. INTRODUCTION Congratulations on your purchase of the EMERALD HOME 20 OFFICE B Device for water purification and electrochemical treatment. You have invested wisely in the well-being of your family, and you have also taken a very important step towards improving your health!
(including free radicals). Antioxidant water from EMERALD HOME 20 OFFICE B Device has a beneficial effect on the entire body, normalizing metabolism and the functioning of internal organs, cleansing toxins, and also strengthening the immune system, improving memory and toning up the body.
Page 5
EMERALD HOME 20 OFFICE B Device is not a medical device. Before using catholyte for preventive or therapeutic purposes, consult a specialist. The information on the properties and methods of using catholyte presented in this section is for reference only and does not apply to medical reports.
3. PRINCIPLES OF WATER TREATMENT The EMERALD Device is high performance and runs on cold tap water, producing up to 20 liters of purified antioxidant drinking water (catholyte) per hour. EMERALD Device ensures high quality of drinking water purification due to the consistent combination of water activation in electrochemical modules and the use of auxiliary environmentally friendly filter elements.
Page 7
Useful information! All water purification and activation processes in EMERALD Devices are as close as possible to what happens to water in living Nature, since the mechanism of fresh water purification in Nature is represented by two main processes: redox reactions and filtration.
The main stages of water treatment in EMERALD Device Stage 1. Anode chamber of the MB-11 electrochemical module Destruction of microorganisms, microbial toxins and biofilms in the water flowing through the anode chamber of the electrochemical module; Oxidative destruction of organic compounds, such as herbicides, pesticides, antibiotics, hormones, antidepressants, surfactants, phenols, petroleum products;...
They can seriously damage the Device. It is necessary to carry out regular maintenance of the EMERALD Device for washing the filter elements and electrochemical modules (see DEVICE MAINTENANCE Section).
Page 10
The socket should not be located directly above the sink or in any other place where water can enter it. Before connecting to the power supply, make sure that the Device and all its elements are dry. During operation, all elements of the EMERALD Device must be dry and not leaking.
5. DEVICE FEATURES Table 1. Specifications Recommended productivity, no more than, liters per hour Water cooling productivity (5–10 C°), l / h Water heating productivity (85–95 C°), l / h Power consumption during water treatment, no more than, W Power consumption during water cooling, W Power consumption during water heating, W Specific electricity consumption, not more than W* h/l Supply voltage - standard socket with grounding (for adapter), V.
Table. 5. Contents of Delivery Item Number, pc. Overall view EMERALD HOME 20 OFFICE B Device. Network cable with an IEC320 C14 plug for connecting the Device to the electrical network (the network cable is built into the Device casing).
Page 13
Table 6. Auxiliary items purchased separately Number, Name Appearance pcs. Activated carbon post filter, replaceable, with quick-release fitting for 1/4" tube with the Add. 1 connection set: fixing clips for fastening the post filter, 2 pcs.; self-tapping screws for mounting fixing clips, 2 pcs. Slim Line 10"...
Description of the main elements on the EMERALD Device casing Fig. 6 shows the main elements of the EMERALD HOME 20 OFFICE B Device, located in the front and rear parts of the casing. For user convenience, the numbering of elements in Fig. 6 and subsequent connecting diagrams is the same.
® General rules for handling John Guest type quick-release fittings The connection of the 1/4" tubes to the fittings is done manually. John Guest® type quick- release connections allow you to repeat the procedures for connecting/disconnecting the tubes and fittings if necessary. When properly connected, the tube enters the fitting hole by 15-18 mm. Cor- rectness and reliability of the connection is checked by the return movement of the tube, after con- necting to the fitting.
This section describes the basic EMERALD Device connection method recommended by the manufacturer. If you use an alternative method of EMERALD Device connecting, you must make sure that the method you choose does not contradict other conditions of this Operating Manual. In case of violation of the EMERALD Device installation and operation conditions, warranty claims may be rejected.
Page 17
CONNECTION DIAGRAM OF EMERALD DEVICE IN OPERATION MODE The EMERALD Device is placed without fastening on a horizontal flat smooth surface. The EMERALD Device connecting procedure in the OPERATION mode is carried out in accordance with the diagram in Fig. 8 and consists of the following stages: Installation of the initial drinking water bottle (3);...
(see PRECAUTIONARY MEASURES and DEVICE SPECIFICATIONS Sections). To comply with electrical safety measures, the electrical outlet the EMERALD Device is connected to must be uninterrupted, have a valid ground contact, and be connected through a residual current device (RCD) or differential circuit breaker (RCBO) with a rated leakage current of...
8. DEVICE OPERATION Basic operating modes STANDBY Mode In STANDBY mode, the Device is connected to the electrical network. The source water bottle is installed in the appropriate slot at the top of the Device. The LED is not lit. The electronic display is off.
Device efficiency. The voltmeter (upper numerical scale) indicates the voltage in volts (V) applied to the electrochemical modules. In the EMERALD Device, the voltage is stable and is 24V. The ammeter (lower numerical scale) indicates the current in amperes (A) that flows in the electrochemical modules during water treatment.
To achieve the maximum quality of water purification and electrical treatment in the EMERALD HOME 20 OFFICE B Device, as well as to ensure drinking water quality standards, the user must regularly flush the Device with a solution of citric acid. With timely and uncomplicated maintenance, your Device will produce clean, high quality antioxidant drinking water with the required characteristics for many years.
60-70 ° C (not higher!). Important! It is not allowed to flush the EMERALD Device with a citric acid solution with a temperature of more than 70°C. This can damage the hydraulic elements of the system! In this case warranty claims may be rejected.
FLUSHING Mode To start the FLUSHING mode, the EMERALD Device must be connected according to the diagram in fig. 14 and be in STANDBY mode. All hydraulic and electrical connections must be securely fixed. The circulating flushing tank must be placed on a level and stable surface (e.g. on the worktop next to the sink, on the floor or on the bottom shelf of the sink cabinet).
Page 24
Device in the OPERATION mode. To increase the useful life of the EMERALD HOME flushing tank and connecting tubes, we recommend that after the FLUSHING mode, wash out thoroughly with warm tap water, dry and remove these elements before the next flushing.
Connecting diagram of the EMERALD Device at the CIRCULATION and HOLD-UP stages The procedure for connecting the EMERALD Device in the FLUSHING mode is performed in accordance with the diagram in fig. 14 and consists of the following stages: Preparing a flushing solution of citric acid in a container (10);...
Connecting diagram for EMERALD Device at the WASHING-OUT stage The procedure for connecting the EMERALD Device at the WASHING-OUT stage is carried out in accordance with the diagram in fig. 15 and consists of the following stages: Installing a bottle of cold tap water (3);...
10. TROUBLESHOOTING GUIDE Table 7. Troubleshooting Guide Problem Probable Cause Remedy Device does not turn 1. The hydraulic and electrical 1. Connect the hydraulic and electrical connections of the Device are connections according to the DEVICE connected incorrectly. CONNECTION section. LED and electronic 2.
Operating Manual. The warranty does not cover: ® EMERALD Device, which has been used for other purposes or in a way that is contrary to the instructions in this Operating Manual; ® Any EMERALD Device that has been used incorrectly, crashed, physically damaged, improperly installed or misused, altered, mishandled, or exposed to adverse external factors (including but not limited to, lightning, flood or fire);...
Device stated in this Operating Manual. The manufacturer and official trading partners are not responsible and do not accept claims if the EMERALD Device was used for other purposes or in a way that contradicts the instructions in this Operating Manual.
EMERALD Devices, as well as to carry out their service and warranty maintenance. The company EMERALD ECOTECHNOLOGIES LLC has the exclusive right to transfer to its official trading partners all the necessary powers for the sale of EMERALD Devices, as well as for their service and warranty maintenance.