  • Page 1 PASSPORT AND OPERATION MANUAL EMERALD HOME 3 FOR PURIFICATION AND ELECTRIAL TREATMENT OF FRESH WATER...
  • Page 2: Table Of Contents

    FOREWORD ..........................2 INFORMATION ON ANTIOXIDANT WATER ..............2 METHODS OF WATER PURIFICATION AND ELECTRICAL TREATMENT .....3 Main stages of water treatment in EMERALD device................... 5 PRECAUTIONARY MEASURE ....................6 CONNECTION OF THE DEVICE ...................8 EMERALD device location under sink......................8 General rules for handling quick fittings like John Guest®.
  • Page 3: Foreword

    The antioxidant water from the EMERALD has a positive effect on the body when it is used as a part of the usual ration. The antioxidant water from the EMERALD protects the body from the action of strong toxic oxidizing agents.
  • Page 4: Methods Of Water Purification And Electrical Treatment

    3. METHODS OF WATER PURIFICATION AND ELECTRICAL TREATMENT The EMERALD is highly productive and runs on cold tap water allowing you to get from 50 to 60 liters of drinking antioxidant water per hour. Electrochemical activation technologies in the EMERALD allowed combining the high- performance purification and the water treatment in order to restore its antioxidant properties.
  • Page 5 The latest technologies used in the EMERALD allow you to get the clean and useful antioxi- dant water while maintaining a neutral level of acid-base balance (pH level). The antioxidant water with the neutral pH level is suitable for regular use in the composition of the usual die- tary.
  • Page 6: Main Stages Of Water Treatment In Emerald Device

    Main stages of water treatment in EMERALD device. Stage 1. Anode chamber of the electrochemical module The microorganisms, microbial toxins and biofilms destroyed in the water flowing through the anode chamber of the electrochemical module; Oxidative destruction of the organic compounds such as herbicides, pesticides, surfactants, phenols, petroleum products and etc.;...
  • Page 7: Precautionary Measure

    4. PRECAUTIONARY MEASURE Important! For normal operation of the EMERALD it is necessary to comply with all re- quirements for its operation and service maintenance specified in this specification and oper- ating manual. Prior to start using the device you are requested to read carefully all instructions. If you have any questions about the connection or operation of the EMERALD you are requested to con- sult with our authorized dealers or call our customer service.
  • Page 8 For proper function the EMERALD outlet shall run faultlessly and it shall have the GROUNDING.
  • Page 9: Connection Of The Device

    In the case of using an alternative method of connecting the EMERALD it is necessary to make sure that the method chosen is not in conflict with the other conditions of this Specification and the operating manual. In case of violation of the terms of installation and operation of the EMERALD the warranty claims may be rejected.
  • Page 10: General Rules For Handling Quick Fittings Like John Guest

    General rules for handling quick fittings like John Guest®. The connection of the white ¼ tube to the fittings can be done manually or using the special key included in the package. Quick-release joints of the John Guest® type allow, if it is necessary, to carry out procedures for connecting / disconnecting the tubes and the fittings multiple times.
  • Page 11: Emerald Device Connection Under The Sink

    Fig. 7 Connection diagram of EMERALD device under the sink 1 - EMERALD device; 2 - line of cold water; 3 - a tube of an entrance of cold tap wa- ter; 4 - outlet tube of purified drinking water; 5 - tee with ball valve, for supplying water to the device;...
  • Page 12: Connection To Cold Water Supply Line

    Connection to cold water supply line. Fig. 8 Connection to cold water supply line Shut off the flow of cold water to the sink and then open the cold water tap on the mixer tap to drop the pressure in the tube; Insert / screw the tee with the ball valve into the gap between the cold water supply and the flexible piping of the mixer tap, see (Fig.
  • Page 13: Clean Water Tap Installation

    Clean water tap installation Drill a hole with a diameter of 12 mm for the tap in the sink and install it (see. Fig. 10). Drilling a hole in the sink should only be done if it is certain that the sink will not be destroyed in this procedure.
  • Page 14: Connection Of The Device To The Electric Network

    Connection of the device to the electric network. The EMERALD device is connected to the electric network in several stages - see Fig. 13. First you need to connect the power supply (adapter) to the network cable. Then you need to connect the power cable to an electrical outlet and insert the plug of the power supply into the power socket of the EMERALD device in the upper left corner of the side of the case.
  • Page 15: Operation Of The Device

    (more than 1 day) then the first 30 liters of purified water shall also be discharged. When you turn on the EMERALD for the first time it is necessary to adjust the speed of the purified water flow (see the “Setting the Flow of Water” section).
  • Page 16: Supply Of Tap Water

    Water flow rate adjustment. Adjust the speed of the water flow through the EMERALD using the water flow regulator (see. Fig. 14 – “3” and Fig. 16) which is located inside the device housing.
  • Page 17: Operation Of The Device With The Connection Under The Sink

    LED integrated in the body of the device (see Fig. 17). Due to the presence of intelligent color indication of the LED, the user can track all the most important parameters of the EMERALD device . The multifunctional indicator allows one to evaluate: The resource of the device, after which it is necessary to flush the de- u ...
  • Page 18: Main Operating Modes

    Main operating modes The EMERALD works in the semi-automatic mode. The built-in monitoring and control device of the EMERALD allows the user to monitor the most important aspects of the device status. STANDBY mode. In STANDBY mode, the device is connected to the mains and to the water supply device, but is in the off state.
  • Page 19: Maintenance Of The Device

    7. MAINTENANCE OF THE DEVICE. To achieve the highest quality of purified water in the EMERALD as well as to ensure the regulatory compliance of water quality the user shall regularly flush the device with the solution of citric acid. With timely and uncomplicated maintenance your device will produce the highest quality drinking water with excellent taste characteristics for many years.
  • Page 20: Preparation Of Citric Acid Washing Solution

    Preparation of citric acid washing solution To carry out the flushing procedure for the EMERALD it is necessary to prepare 1 (one) liter of citric acid washing solution in the tank of the flushing device (Fig. 18 – “5”). The flushing solution of citric acid is prepared on the basis of 200 grams of the citric acid and a half liter of water.
  • Page 21: Flushing Mode

    FLUSHING mode. To start FLUSHING mode EMERALD device must be in STANDBY mode (the device is connect- ed to the electrical network, but is turned off. The LED indicator is off). Then user should do the fol- lowing: Shut off the tap water supply to the device (see Fig.
  • Page 22 FLUSHING mode is still going on. The next steps shall be carried out: Disconnect the flushing device from the EMERALD device by unplugging the electric cable of the flushing device (2) from the socket (9) and disconnecting the hydraulic supply hose for citric acid solution (3) from the fitting (6).
  • Page 23 After 10 minutes of WASH OUT stage, the LED will light up in standard green color, indi- u  cating that the FLUSHING mode has been successfully finished and the device has entered the full OPERATION mode (is ready for normal usage). Некоторые...
  • Page 24: Troubleshooting Guide

    8. TROUBLESHOOTING GUIDE. Table 1 Troubleshooting Guide Concern Probable reason Elimination The device does not Hydraulic electrical 1. Connect the hydraulic and electrical turn on. The LED of connections device connections in accordance with section 5 the sensor disc does connected incorrectly.
  • Page 25: Warranty Responsibilities

    Specification and Operating Manual. The term of warranty service of the EMERALD is 1 year from the date of its sale but not more than 24 months from the date of its production. In case of absence of the date of sale and the stamp of the trading organization the period of warranty service starts from the date of production.
  • Page 26: Handling And Storage

    The manufacturer and the official trading partners are not liable and do not accept the claims if the EMERALD was used not for its intended purpose or in a way that contradicts the instructions of this specification and operating manual.
  • Page 27: Technical Characteristics

    11. TECHNICAL CHARACTERISTICS. Table 2. Specification Recommended capacity of purified water, liters per hour 50 - 60 Power consumption, not more, W Specific power consumption, W * h / l Supply voltage - standard socket with grounding (for the adapter), V. 110 ÷...
  • Page 28: Delivery Package

    Specification and operating manual Add. Additional diverter for the tap with a set of nozzles for alternative connection of Opt. the EMERALD above the sink to the tap Add. Additional housing with softener cartridge (for regions with the excessively hard Opt.
  • Page 29: Certificate Of Acceptance And Sale

    EMERALD as well as to provide them with service and warranty service. EMERALD ECOTECHNOLOGIES LLC has the exclusive right to transfer to its official trading partners all the necessary powers for the sale of EMERALD devices as well as for the implementation of the service and warranty service.
  • Page 30: Appendix No 1. Certificates

    APPENDIX No 1. CERTIFICATES 1. CERTIFICATE OF CONFORMITY OF QUALITY MANAGEMENT SYSTEM REQUIREMENTS GOST R ISO 9001-2015 (ISO 9001-2015) 2. CERTIFICATE OF CONFORMITY OF THE EAC CUSTOMS UNION...
  • Page 31 EXPERTS' REPORT ISSUED BY ROSPOTREBNADZOR...
  • Page 32 2. VOLUNTARY CERTIFICATE OF COMPLIANCE WITH GOST R 3. DECLARATION OF COMPLIANCE WITH EAC OF THE CUSTOMS UNION...
  • Page 33: The Sink

    (4) (Fig. 2.1). For switching off the device the sensor key shall be pressed again. Please note! The EMERALD is designed only for the treatment of cold tap water. It is not allowed to pass hot water from the tap through the device.