Maintenance; Troubleshooting - Graco TRITON D Series Instructions-Parts List Manual

1:1 diaphragm pump
Table of Contents

Advertisement

Tightening Threaded Connections
Before each use, check all hoses for wear or damage.
Replace as necessary. Check that all threaded con-
nections are tight and leak-free.
NOTE: Periodically, re–torque fluid cover screws (38)
to 10 ft–lb (13.6 NSm).
Cleaning
Clean the outside of the equipment daily, using a soft
cloth and compatible solvent.
Clean the suction tube (L) and inlet strainer daily, using
a compatible solvent.
Clean the air filter (D) in your main air line at least
once a week.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 11.
PROBLEM
Pump will not run.
12
309303

Maintenance

Storage
Before storing the pump, always flush it and relieve
pressure.
Preventive Maintenance Schedule
Establish a preventive maintenance schedule, based
on the pump's service history. This is especially impor-
tant for prevention of spills or leakage due to dia-
phragm failure.

Troubleshooting

1. Relieve the pressure before checking or servicing
2. Check all possible problems and causes before
CAUSE
Closed air line valve.
Inadequate air supply, or clogged/
restricted air line.
Clogged pump, fluid line, or spray
gun.
Stuck or damaged pump air valve.
Ruptured diaphragm.
Air valve plate installed incorrectly.
the equipment.
disassembling the pump.
Open valve.
Increase air supply. Do not exceed
maximum air inlet pressure.
Open or clear air line.
Clean air filter.
Clear, service. Flush regularly. Do
not allow fluid to set up in the pump
and lines.
Disassemble and clean air valve.
Replace worn parts. See page 18.
Use filtered air.
Replace diaphragms. See page 17.
Align plate with center housing. See
page 19.
SOLUTION

Advertisement

Table of Contents
loading

This manual is also suitable for:

Triton c seriesTriton 233500Triton 233501Triton 233507

Table of Contents