3

Technical description of the burner

3.1

Technical data

Type
Output - Thermal power
(with air at 20 °C)
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
 Gas oil is not permitted on low level discharge of flue gas products.
3.2

Burner description

3
8
1
Pump
2
Control-box
3
Reset button with lock-out lamp
4
Flange with insulating gasket
5
Air damper adjustment screw
6
Pump pressure adjustment screw
7
Pressure gauge port
8
Flame sensor
Technical description of the burner
Kerosene, viscosity 1.6 – 6 mm
Gas oil, viscosity 4 – 6 mm
Kerosene, maximum pressure 10 bar (145 psi)
Gas oil, maximum pressure 15 bar (218 psi)
GRILL
SNORKEL
5
4
D6314
7
GB
744T5K - 744LD3
2.8 - 4.5 kg/h
33.5 - 54 kW
2
/s at 20 °C
2
/s at 20 °C  (Hi = 11.86 kWh/kg)
Single phase, ~ 50Hz 230 V ± 30%
Run current 0.7 A – 2700 rpm – 283 rad/s
4.5 F
Secondary 8 kV – 16 mA
0.16 kW
1
(Hi = 11.97 kWh/kg)
Tab. A
2
6
7
Fig. 1