Models Equipped With Fuse Holder Extractors; Models Equipped With Safety Caps - ABB PVI-8.0-TL-OUTD Product Manual

Solar inverters
Hide thumbs Also See for PVI-8.0-TL-OUTD:
Table of Contents

Advertisement

Depending on the presence of fuse holder extractors or safety caps, fol-
low the corresponding procedure:
M
odels equipped with fuse holder extractors
5a. Remove the fuse holder by pressing its handle.
6a. Extract the fuse to be replaced from the fuse holder by releasing the
retaining clip.
7a. Insert the replacement fuse into the fuse holder, checking that it is
secured by the retaining clip.
8a. Insert the fuse holder back in its original position.
M
odels equipped with safety caps
5b. Remove the safety cap.
6b. Extract the fuse to be replaced from the fuse holder.
7b. Insert the replacement fuse into the fuse holder, checking that it is
correctly fitted.
8b. Replace the safety cap back in position.