MAINTENANCE
INSPECTION
Use an applicable solvent and clean the remaining
material from all flow meter parts.
Examine all following parts for wear and damage:
1. The gear shafts (r) must measure the same
diameter at the ends and center. Replace the
gear shaft set if a shaft does not measure the
same at the three locations or if there are scores,
scratches, or damage to the shaft.
2. The gear teeth (q) must not be worn, chipped,
pitted, broken, or missing. Replace the gear set if
there is damage to a gear.
3. The gear shaft bearing(s) must not be worn,
pitted, or have scores or scratches. Replace the
gear set if a bearing has damage or the gears
wobble on the shafts.
4. The shaft bearings (u) in the top flow meter body
(o) must not be worn, pitted, or have scores or
scratches.
Put the gear shafts into the top body bearings
and try to wobble them. Replace the top body if a
bearing has damage or the gear shafts wobble in
the bearings.
5. The flow meter top's mating face (t) must not be
gouged, scored, scratched, or pitted. Replace the
top body if there is damage.
77-3154-R1 (05/2023)