Carlisle Ransburg 310-9000 Service Manual page 19

Standard flow meter
Table of Contents

Advertisement

EN
9. Divide the top (o) and bottom (m) flow meter
body halves. Put the flow meter body halves in a
clean work area with the mating surfaces pointed
up. Do not let these surfaces get damaged,
especially where the o-ring gasket is set.
If separation of the halves is not easy, do not pry
apart the body halves with a screwdriver or other
such tool. Damage to the mating surfaces, gear
shafts, or shaft bearings can occur.
An alternative method of separation is to:
a) Put two socket head cap screws (n) through
opposite sides of the flow meter and give the
screws a few turns each.
b) Tightly hold the top body, then tap the screw
heads with a soft mallet until separation is
complete.
10. Remove and discard the o-ring gasket (p).
Discard the used o-ring gasket.
cannot be reused, but must always be replaced
with new ones during flow meter body servicing.
11. Remove the gears (q) and shafts (r) from the
shaft bores in the measuring chamber.
www.carlisleft.com
O-ring gaskets
19/34
m
77-3154-R1 (05/2023)
MAINTENANCE
o
p
q
r