Machine Maintenance; Daily Maintenance - Tennant Nobles TYPHOON 1610P Operator And Parts Manual

Table of Contents

Advertisement

Available languages

Available languages

3. Hang drain hose elbow over edge of drain sink
(Figure 17).
FIG. 17
4. Pull up on drain lever and turn on switch
(Figure 18).
FIG. 18
5. Vacuum motor will pressurize tank and force
water up into drain sink.
Tyhoon 1610P/1612 (07- -02)

MACHINE MAINTENANCE

To keep machine in good working condition, simply
follow machine's daily, weekly and monthly
maintenance procedures.
WARNING: Hazardous Voltage. Shock or
electrocution can result. Unplug machine before
servicing.

DAILY MAINTENANCE

(Every 4 Hours of Use)
1. Drain and rinse recovery tank after wet
vacuuming.
2. Remove and clean float shut--off screen from
recovery tank (Figure 19).
FIG. 19
3. Clean squeegee blades with a cloth. Replace
blades when they become worn.
4. Check bag for fullness, empty bag at 3/4 full.
5. Wipe machine housing with a nonabrasive,
nonsolvent cleaner.
6. Check cords and cord grips for damage. If worn or
damaged, replace immediately. Coil cord neatly.
ATTENTION: Always have float shut- -off screen in
place before operating. During wet operation, the
shut- -off float protects the vacuum motor from
water. During dry vacuuming, the float screen can
provide limited protection for a faulty filter bag.
7. Inspect vacuum hose regularly for holes, loose
cuff or clogged debris.