Installing And Commissioning - Siemens SIMATIC RF1040R Operating Instructions Manual

Simatic ident
Table of Contents

Advertisement

Installing and commissioning

The procedure for installing and commissioning the reader depends on the interface over
which the reader is being operated.
Installation and commissioning via the USB interface
Proceed as follows to install and commission the SIMATIC RF1000 reader via the USB
interface:
1. Connect the reader to the PC or Panel using the USB cable.
Reaction: The message "A USB device was installed successfully." appears.
2. Copy the DLL drivers and the demo application on your PC using the installation file
"RF1000R.exe".
You will find the file on the Internet on the pages of the Industry Online Support
(https://support.industry.siemens.com/cs/ww/en/view/109741590).
3. Start the demo application by double-clicking on the file "AccessControlDemo.exe".
4. Program the reader using the demo application and the DLL functions.
You will find more information on the demo application in the section "The demo application
(Page 51)".
Installation and commissioning via the RS232 interface
Proceed as follows to install and commission the SIMATIC RF1040R/RF1070R reader via
the RS232 interface:
1. Connect the reader to the communications module or the controller with the RS232 cable.
2. Configure the freeport protocol (e.g. data bits, parity, stop bits, transmission speed).
3. Program the blocks of the controller.
You will find more information on the freeport protocol in the section "Programming via the
RS232 interface (Page 36)".
SIMATIC RF1000
Operating Instructions, 11/2019, C79000-G8976-C432-06
5