Veridian Healthcare 08-359 Manual

Veridian Healthcare 08-359 Manual

9-second digital thermometer

Advertisement

Quick Links

PROBE TIP
THANK YOU FOR PURCHASING THIS 9 SECOND DIGITAL THERMOMETER. READ THESE INSTRUCTIONS
CAREFULLY TO ENSURE PROPER AND SAFE OPERATION OF YOUR THERMOMETER.
PLEASE READ AND SAVE THESE INSTRUCTIONS
This product is not intended to diagnose or treat any health problem or disease and should not be used as
a substitute for the consultation and advice of a physician or other medical professional.
Choking Hazard: thermometers should only be used under the supervision of an adult; removable cap and
battery may be harmful if swallowed.
This thermometer should be held during use; the patient should be seated or lying down during readings.
Before use, it is recommended that the patient avoid eating, drinking, smoking or exercising for at least
twenty minutes prior to taking a measurement. Never walk, run or talk during a measurement.

FAHRENHEIT CELSIUS SWITCHABLE FEATURE

This unit takes measurements in both Fahrenheit and Celsius. While the unit is OFF, press and hold the POW R
button. After the brief self-test, the unit will show the last reading in either °F or °C. Continue to hold the
POW R button, and display will change the mode and display the new temperature reading mode. Release
the POW R button and begin your reading.

MEMORY RECALL

This unit includes a recall of the last measurement taken. When the unit is OFF, press the POW R button to turn
the unit on, and release. After the self-test, the unit will briefly show the last reading with an'M'on the display .

OPERATING INSTRUCTIONS

Wipe or dip the probe tip with isopropyl alcohol to clean before use; apply a probe cover if using.
Press and release the POW R button to activate the thermometer. The unit will beep and the display will show
all of the digital display symbols as it performs a self-test before showing the last reading in memory.
'Lo' with a flashing °F(°C) will appear in the display, followed by a brief flash of 98.6°F(37°C); the display will
return to the 'Lo' with flashing °F(°C), indicating that the thermometer is ready for measurement.

ORAL USE

Approximate measurement time: 10-20 seconds — Place the probe under the tongue as
near as possible to a heat pocket as noted in the diagram. Readings will be progressively
lower the further the probe is from the indicated heat pockets. Hold the thermometer in
place during the reading; do not bite down on the thermometer. The mouth must remain
closed to ensure accurate results.

UNDERARM (AXILLARY) USE

Approximate measurement time: 20-30 seconds — Place the probe tip under the arm so that
the tip is touching skin; hold the thermometer parallel, slightly angled upwards. Position the arm
across the chest to ensure the tip is completely covered. Underarm temperature readings are
generally 1°F lower than oral readings.

RECTAL USE

Approximate measurement time: 9 seconds — Apply a probe cover and use a water-soluble
lubricant for easier insertion. Lay the patient on their side or stomach with their legs hanging down. Gently
insert the tip of the probe NO MORE THAN 1 INCH into the rectum; stop immediately if you detect resistance.
Always hold the thermometer in place during measurement. Rectal temperature readings are generally 1°F
higher than oral readings.
9-SECOND
DIGITAL THERMOMETER
MODEL #: 08 359
DIGITAL LCD DISPLAY
POWER BUTTON
BATTERY CAP
HEAT
HEAT
POCKET
POCKET

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 08-359 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Veridian Healthcare 08-359

  • Page 1 9-SECOND DIGITAL THERMOMETER MODEL #: 08 359 DIGITAL LCD DISPLAY PROBE TIP POWER BUTTON BATTERY CAP THANK YOU FOR PURCHASING THIS 9 SECOND DIGITAL THERMOMETER. READ THESE INSTRUCTIONS CAREFULLY TO ENSURE PROPER AND SAFE OPERATION OF YOUR THERMOMETER. PLEASE READ AND SAVE THESE INSTRUCTIONS This product is not intended to diagnose or treat any health problem or disease and should not be used as a substitute for the consultation and advice of a physician or other medical professional.
  • Page 2 PROBE COVER USE Disposable, hygienic probe covers are recommended for use with stick thermometers to prevent contamination. Probe covers are intended for one-time use only; a new probe cover should be used with each application. Probe covers can commonly be found at your local mass market or drug-store retailer. CARE AND CLEANING INSTRUCTIONS Store the unit in the provided protective case when not in use.

Table of Contents