Gas-Fired Pool and Spa Heater | Installation & Operation Manual
®
7.3.3 To Stop the Heater and Prevent Firing
After Connecting to An External Controller
• Turn power to the heater ON. The heater display
shows: JANDY REMOTE ONLINE PUSH MENU
TO DISABLE.
7.3.4 To Revert Heater Control Back to Local
Heater User Interface
To revert the heater back to Standalone without
disconnecting the RS-485:
• Make sure the pool heater is OFF.
• Press and hold MENU, then the POOL and SPA
buttons for 5 seconds to access Service Setup
mode.

Section 8. Operating Instructions

Follow the instructions outlined below to start
the heater. Refer to the Lighting and Shutdown
Instructions label on the inside lid panel of the
heater. See Figure 20
8.1

Important Safety Instructions

READ BEFORE YOU START
• This appliance does not have a pilot light. It
is equipped with an ignition device, which
automatically lights the heater. Do NOT try to light
the burners by hand.
8.1.1 What To Do If You Smell Gas
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier,
call the fire department.
• Use only your hand to switch on or off the gas
control switch. Never use tools.
• After pressing menu, the display will show
JANDY REMOTE OFFLINE PUSH MENU TO
ENABLE.
NOTE: The display will revert back to OFF 1 minute after
the last key press.
• Press Up or Down to display REMOTE.
• Press MENU, REMOTE OFF (default) is displayed.
• Use Up or Down to scroll through the Remote
options until STANDALONE is displayed, then
press MENU to select.
• Press POOL or SPA to exit Service Setup mode.
All questions should be directed to technical support
at 800.822.7933. Additional information can be
found at www.jandy.com.
WARNING
If you do not follow the instructions below exactly, a fire or explosion
may result, causing property damage, personal injury or loss of life.
• BEFORE OPERATING, smell all around the
appliance for gas. Be sure to smell next to the
floor because some gas is heavier than air and will
settle on the floor.
• If the gas control switch appears broken or will
not move, don't try to repair it, call a qualified
service technician. Force or attempted repair may
result in fire or explosion.
• Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to replace
any part of the control system which has been
under water.