3. Press again the encoder 21, LED 14 will flash. Press the encoder 21 for the
third time. On the display will appear "ON". The function will be automatically
saved and LED 25 – main welding current will become active.
4. One can set off the pulse similarly. Just select "OFF".

GETTING STARTED

Getting started must be consistent with technical data and conditions of use.
Insert the mains plug into a suitable 1x230 V mains socket. The supply fuses or
circuit breaker should correspond to the technical data in section 3. Switch the
machine on by the ON/OFF switch 6.
GETTING STARTED MMA – COATED ELECTRODE
1. Set the method switch 17 to position 15 MMA.
2. Connect the welding cables to the panel quick connectors 3 and 5 (+ - )
according the instruction on the electrodes packing.
3. Set the welding current by means of encoder 21. The values will be showed
on the display 13.
4. You may adjust HOT START and ARC FORCE similarly to EN EXAMPLE OF
SETTING.
NOTE
5.
this mode the terminals (5) and (6) are under current.
6. Insert the coated electrode into the electrode holder and you may start
welding.
GETTING STARTED TIG
1. Fit the TIG Torch to the Panel quick connector - 3 and fasten it by turning the
connector to the right.
2. Connect the work lead to Panel quick connector + 5 and fasten it by turning
the connector to the right.
3. Connect the to the reduction valve on the gas cylinder and on the Gas inlet
connector 8.
4. Connect the gas hose of the TIG torch onto Gas outlet connector 2.
5. Connect the torch control connector onto the matching connector 4.
6. Connect the work clamp to the work piece or at the welding table.
7. Set the method switch 17 to desired TIG method.