2. TIG Adjusting the gas flow - it is not possible to weld in this
position
3. TIG LA start 4T
4. TIG LA start 2T
5. TIG HF start 4T
6. TIG HF start 2T
TIG LA 4T – Lift Arc ignition TIG, four stroke - position of the
18
method switch 17
TIG LA 2T – Lift Arc ignition TIG - position of the method switch 17,
19
the start current and end current are set to 5 A, impossible to
change.
TIG HF 4T –TIG HF ignition, four stroke - position of the method
20
switch 17
ENCODER
1. Every press of the encoder switches between selecting
mode of the parameter to be set and setting mode of the
selected parameter
21
2. By means of turning selects the parameters to be set
respective sets the selected parameters.
3. Sets the current 25 – that function is active strait after
switching the machine ON or if no pressing of the
encoder was done.
22
LED pre gas time - only TIG (0-1 s, default 0,1 s)
23
LED start current - only TIG (5-160 A, 5-200 A, default 50 A)
24
LED up slope time - only TIG (0-10 s, default 0 s)
25
LED welding current – all methods
LED lower current – only TIG, just in case the pulse LED 14
26
illuminates (5-160 A, default 64 A; 5-200 A, default 64 A)
LED pulse frequency - only TIG, just in case the pulse LED 14
27
illuminates (0,5-100 Hz, default 100 Hz)
LED pulse width - only TIG, just in case the pulse LED 14
28
illuminates (5-100%, default 50%)
29
LED down slope time - only TIG (0-10 s, default 0 s)
30
LED end current - only TIG (5-160 A, 5-200 A, default 5 A)
31
LED post gas time - only TIG (0,1-10 s, default 10 s)
TIG HF 2T –TIG HF ignition, two stroke - position of the method
32
switch 17