PRINCIPLE OF SETTING PARAMETERS
1. The machine will be the Main Mode after switching ON - LED 25 will
illuminate and turning the encoder 21 will change main welding current
2. Turning the encoder 21 changes parameters.
3. Pressing the encoder 21 activates function of selecting a new parameter to
be set. That function will stay active just for 3 s. In case there is no movement
of the encoder during the period of those 3 s the function deactivates and the
machine switches automatically into the Main Mode.
4. After selection of a LED of a parameter to be set, appropriate LED will start
flashing. That function will stay active just for 3 s. It is possible to change the
value of the appropriate parameter by means of encoder 21 during that time.
5. To save the setting press the encoder 21 or wait for more than 3 s
6. The machine will switch back to the Main Mode after any change of setting 3
s later of last movement of the encoder 21.
EN EXAMPLE OF SETTING
1. Select method
2. Press the encoder 21, then by means of turning the encoder select
LED 24
3. Press again the encoder 21, LED 24 will start flashing. Now you can change
the up slope time by means of turning the encoder 21.
4. Press the encoder 21 third time. That will save the change of the parameter.
In case you omit to press the encoder for the third time the machine will save
the parameter change automatically after 3 s of no movement of the encoder
21. LED 25 will illuminate then.
SELECTING PULSE MODE
1. Select the required TIG method by means of method switch 17, LED 25 will
illuminate
2. Press the encoder 21, then by means of turning the encoder select
LED 14