7.4.1 Cautions for Individual Louver Setting
(1) The individual louver setting is available up to 16 indoor units by one wired controller.
The connection more than 17 indoor units are not available.
Individual
Louver
Wired
Controller
(PC-ARF1)
(2) The individual louver setting in the same refrigerant cycle are available up to 4 indoor units without the
transition wiring for the wired controller.
Wired
Controller
(PC-ARF1)
NOTE:
When the individual louver is set, the indoor unit shall be seen from the place of the wired controller.
In the case of connecting the multiple indoor units, pay attention to the positional relationship between
wired controller and the indoor units.
(3) This "Individual Louver Setting" is NOT available with 2 (two) wired controllers.
(4) The individual louver function is not for blocking the air outlet. If the air outlet is blocked, 3-Way Outlet
Parts Set shall be used.
NOTE:
The air outlets can not be closed individually by the individual louver setting.
34
Individual
Louver
Maximum 16 Indoor Units
Individual
Individual
Louver
Louver
Individual
Louver
Wired
Controller
(PC-ARF1)
Individual
Individual
Louver
Louver
Individual
Individual
Louver
Louver
Individual
Louver
Individual
Louver
A10762300A-rev.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RPC-2.0FSR and is the answer not in the manual?

Table of Contents