G.) FUEL FILTER
CLEAN TWICE PER HEATING SEASON OR AS NEEDED.
Tank Fuel Filter
- Remove fan guard.(See page 11).
- Disconnect fuel line (B) from pump and pump
fuel filter assembly with 3/8" wrench (See
Figure 13)
- Remove two screws that fix bracket-filter to shell
lower and remove bracket-filter.
- Carefully pry fuel filter loose from fuel tank
withflat end of screw driver.
- Wash fuel filter and fuel lines with clean
kerosene.
- Replace fuel filter into fuel tank.
- Connect fuel lines (B) to pump and pump fuel
filter assembly.- Reinstall fan guard.
- Replace bracket-filter to shell lower.
- Carefully pry fuel filter loose from fueltank with
flat end of screw driver.
- Wash fuel lines and fuel filter withclean
kerosene.
Pump Fuel Filter
- Remove fan guard.(See page 11)
- Unscrew (C.W) filter bottom from
filter top
with adjustble pliers.
- Remove fuel filter, gasket, magnet
from filter
bottom.(See Figure 14)
- Wash filter bottom with clean
kerosene.
- Wipe inside of filter bottom dry with
clean cloth.
- Wash Fuel filter in clean kerosene.
- Remove dirt attached magnet.
- Put clean magnet, fuel filter and gasket
back in filter bottom.
- Tighten firmly.
PUMP FUEL FILTER ASSEMBLY
FUEL FILTER
Figure 13. Remove Tank Fuel Filter
Figure 14. Fuel Pump Filter
12
PUMP
SCREW
SHELL LOWER
BRACKET-FILTER
FUEL LINE(B)
FILTER TOP
GASKET
FUEL FILTER
MAGNET
FILTER BOTTOM