3. Install the 2 compressor filters and close the 2 caps.
If you cannot fully clean the compressor filters or if they
are damaged, it is necessary to replace them.
To clean the filter in the water
separator
CAUTION:
washer to clean the filter. Do not hit the filter
with force to clean it.
1. Remove the filter in the water separator. Refer to
replace the filter in the water separator on page 20 .
2. Clean the filter with warm water.
3. Dry the filter with pressurized air.
4. Install the filter. Refer to
water separator on page 20 .
To clean the primary filters
WARNING:
intake when the pulse cleaning cycle runs. If
the air intake is not closed, dust can come in
to the air. The dust particles are dangerous
to your health.
1. Start the product. Refer to
page 11 .
2. Stop the fan. Refer to
12 .
3. Keep the compressor on for 30 minutes while the
product is not in operation. Pressurized air goes
through the primary filters and cleans them.
To do a check of the V-belt tension
WARNING:
cover when the product is disconnected from
the mains outlet and the motor has fully
stopped.
WARNING:
without the V-belt cover installed.
1. Stop the product. Refer to
page 12 .
18
Do not use a high-pressure
To replace the filter in the
Always close off the air
To start the product on
To stop the product on page
Only remove the V-belt
Do not operate the product
To stop the product on
2. Remove the V-belt cover.
To
3. Examine the V-belt for damages and wear. Replace
the V-belt if it is necessary.
4. Push the V-belt with your tumb to examine the
tension. If you can push the V-belt a distance of 10–
15 mm/0.4–0.6 in (A), the tension is correct.
5. Do the steps that follow to adjust the tension of the
V-belt if it is necessary
a) Loosen the 4 nuts.
A