912SE: Installation, Start-up, Operating and Service and Maintenance Instructions
Venting for this furnace shall follow all Local codes for Category IV
venting systems. This furnace is CSA approved for venting with
PVC/ABS DWV venting systems. This furnace is also CSA approved
for venting with M&G DuraVent
polypropylene venting systems using single wall straight and flex, and
required fittings (elbows, reducers, increasers, connectors, adapters)
only.
NOTE: THESE INSTRUCTIONS DO NOT CONTAIN DETAILED
INSTALLATION
INSTRUCTIONS
VENTING SYSTEMS. Refer to the polypropylene venting system
manufacturer's installation instructions for the polypropylene venting
system installation.
NOTE: When using polypropylene venting systems, all venting
materials used, including the vent terminations, must be from the same
manufacturer.
Special Venting Requirements for Installations in
Canada
Installation in Canada must conform to the requirements of CSA B149
code. Vent systems must be composed of pipe, fittings, cements, and
primers listed to ULC S636. The special vent fittings, accessory
concentric
vent
termination
KGAVT0801CVT) and accessory external drain trap available from the
furnace manufacturer have been certified to ULC S636 for use with
those Royal Pipe and IPEX PVC vent components which have been
certified to this standard. In Canada, the primer and cement must be of
the same manufacturer as the vent system – GVS-65 Primer (Purple) for
Royal Pipe or IPEX System 636, PVC/CPVC Primer, Purple Violet for
Flue Gas Venting and GVS-65 PVC Solvent Cement for Royal Pipe or
IPEX System 636
t, PVC Cement for Flue Gas Venting, rated Class
(1)
IIA, 65 deg C. must be used with this venting system - do not mix
primers and cements from one manufacturer with a vent system from a
different manufacturer. Follow the manufacturer's instructions in the use
of primer and cement and never use primer or cement beyond its
expiration date.
The safe operation, as defined by ULC S636, of the vent system is based
on following these installation instructions, the vent system
manufacturer's installation instructions, and proper use of primer and
cement. All fire stop and roof flashing used with this system must be UL
listed material. Acceptability under Canadian standard CAN/CSA B149
is dependent upon full compliance with all installation instructions.
Under this standard, it is recommended that the vent system be checked
once a year by qualified service personnel.
The authority having jurisdiction (gas inspection authority, municipal
building department, fire department, etc.) should be consulted before
installation to determine the need to obtain a permit.
*IPEX System 636™ is a trademark of IPEX Inc.
WARNING
!
CARBON MONOXIDE POISONING HAZARD
Failure to follow the instructions outlined below for each appliance
being placed into operation could result in carbon monoxide poisoning
or death.
For all venting configurations for this appliance and other gas
appliances placed into operation for this structure, provisions for
adequate combustion, ventilation, and dilution air must be provided in
accordance with:
U.S.A. Installations: Section 9.3 of current edition of NFPA 54/ANSI
Z223.1, Air for Combustion and Ventilation and applicable provisions
of the local building codes.
Canadian
Installations:
CAN/CSA-B149.1. Venting Systems and Air Supply for Appliances
and all authorities having jurisdiction.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
PolyPro
or Centrotherm Innoflue
R
R
FOR
POLYPROPYLENE
kits,
(KGAVT0701CVT
Part
8
of
current
edition
Consignes spéciales pour l'installation de
ventilation au Canada
L'installation faite au Canada doit se conformer aux exigences du code
R
CSA B149. Ce systême de ventillation doit se composer de tuyaux,
raccords, ciments et apprêts conformes au ULC S636. La tuyauterie de
ventilation des gaz, ses accessoires, le terminal concentrique mural
(KGAVT0701CVT or KGAVT0801CVT) ainsi que l'ensemble du drain
de condensation extérieur fourni par le fabricant de cette fournaise ont
été certifiés ULCS 636 pour l'application des composantes Royal Pipe,
IPEX PVC qui sont certifiées à ce standard. Au Canada, l'apprêt et le
ciment doivent être du même fabricant que le système d'évacuation.
L'apprêt GVS-65 (Purple) et le ciment-solvant GVS-65 doivent être
utilisé avec les Royal Pipe. Système IPEX 636, apprêt PVC/CPVC,
Purple pour évacuation des gaz de combustion et système IPEX
636(1)t, ciment PVC pour évacuation des gaz de combustion, coté classe
IIA, 65 deg C. doivent être utilisés avec le système d'évacuation IPEX
636 – Ne pas combiner l 'apprêt et le ciment d'un manufacturier avec un
système d'évacuation d'un manufacturier différent.
Bien suivre les indications du manufacturier lors de l'utilisation de
l'apprêt et du ciment et ne pas utiliser ceux-ci si la date d'expiration est
atteinte.
or
L'opération sécuritaire, tel que définit par ULC S636, du système de
ventilation est basé sur les instructions d'installation suivantes, ainsi que
l'usage approprié de l'apprêt et ciment. Tout arrët feu et solin de toit
utilisés avec ce système doivent être des matériaux listés UL.
L'acceptation du standard Canadien CAN/CSA B149 est directement
relié à l'installation conforme aux instructions ci- haut mentionnées. Le
standard Canadien recommande l' inspection par un personel qualifié et
ce, une fois par année.
Les autoritées ayant juridiction (inspecteurs de gas, inspecteurs en
bâtiments, département des incendies, etc) devraient être consultées
avant l'installation afin de déterminer si un permis est requis.
RECOMMENDED SUPPORT FOR VENT
TERMINATION
It is recommended that sidewall vent terminations of over 24 inches
(0.6 M) in length or rooftop vent terminations of over 36 inches (1 M)
in length be supported by EITHER the factory accessory vent
termination kit or field-supplied brackets or supports attached to the
structure. A factory accessory vent termination kit may be used for
direct vent terminations. Termination kits are available for 2-in. or 3-in.
pipe. See
Table 12
for available options.
of
29
NOTICE
!

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents