Section A; Specifications - Toyostove Laser 530 Assembly, Installation And Operation Instructions

Laser clean heating system/vented heater
Table of Contents

Advertisement

Laser 530_Type A_US.qxd 15.3.26 16:13 ページ 2

SECTION A:

SPECIFICATIONS

Model:
Heater Efficiency:
Heat Rating:
Fuel Consumption:
Fuel system:
Fuel Type:
Dimensions (W × H × D):
Weight:
Vent Pipe Hole:
Maximum Length of Vent Pipe System:
Electrical Rating:
Typical Room Size (3):
(1)
Heat and vaporized water are produced by the combustion process of this heater. This rating does not take
into account heat loss due to condensation of water vapor.
(2)
External tank to be purchased from local suppliers.
(3)
0° F Heat Load
20° F Heat Load = 20 BTU/ft
Room size for which this heater is suitable will vary depending on outside temperature, house insulation,
window size, and other factors.
2
2
= 24 BTU/ft
/hr
2
/hr
Laser 530
92.4%
High - 22,000 BTU/h
Med - 15,000 BTU/h
Low -
8,000 BTU/h
High - 0.165 gal/h (0.625 L/h)
Med - 0.113 gal/h (0.428 L/h)
Low - 0.060 gal/h (0.227 L/h)
External tank (2)
1-K kerosene (ASTM D3699)
Low Sulfur No.1 Fuel (ASTM D396 S500)
Ultra Low Sulfur Diesel Fuel (ULSD) or
Ultra Low Sulfur Heating Oil (ULSHO) (ASTM D975 S15)
19-5/8" × 23-5/8" × 16-1/2" (496 × 600 × 418 mm)
38 lbs. (17 kg) Empty
2-3/4" – 3" (7.0 – 7.5 cm) diameter
10ft. (3 m), 3 bents or less
120 Volts AC, 60 Hz
Preheat - 240W
Burning - 50W
920 square feet ( 0°F)
1150 square feet (20°F)

Advertisement