Installation Of Heater And Flue Pipe - Toyostove Laser 530 Assembly, Installation And Operation Instructions

Laser clean heating system/vented heater
Table of Contents

Advertisement

Laser 530_Type A_US.qxd 15.3.26 16:14 ページ 26
IMPORTANT: Check and comply with all state and local codes that may apply to vented heaters before beginning
installation.
NOTE: This heater is designed to be used at altitudes up to 3,000 ft. above sea level.
For use at altitudes higher than 3,000 FT. and up to 6,000 FT., adjustments to the heater must be made.
Consult with your dealer.
MINIMUM CLEARANCE TO COMBUSTIBLE AND NONCOMBUSTIBLE CONSTRUCTION
1.
Select heater location. Allow clearances as indicated below between heater and all other materials.
(See Fig. 1)
Note: These clearance are necessary to allow properly circulation and to have heater work affectively.
2.
Make sure that the outside area to where the flue pipe will reach is clear of any objects.
(See Fig. 2 & 3)
CAUTION! The standard flue pipe installation, as shown in Fig. 2, is for wall thickness from 4 in. to 9 in. ONLY.
Note: For wall thickness more than 9 in., refer to page 22 for available flue pipe extensions.
Note: The flue pipe can be installed through any standard building materials.
Combustible object
Not less than 2 ft.
26

INSTALLATION OF HEATER AND FLUE PIPE

More than 1 ft.
More than 5 ft.
Combustible object
NonCombustible
object
Not less
than 2 ft.
45˚
Not less
than 1 ft.
Flue pipe
*Not less
than 8 in.
Fig. 2
More than 2 ft.
More than 4 inches
More than 1 ft.
Fig. 1
Not less
than 1.5 ft.
* Be sure this
clearance will
be maintained
after snowfalls,
etc.
Not less
than 1.5 ft.
Fig. 3