SECTION A:
SPECIFICATIONS
Model:
Heater Efficiency:
Heat Rating:
Fuel Consumption:
Fuel System:
Fuel Type:
Dimensions (W × H × D):
(Includes drip tray)
Weight:
Vent Pipe Hole:
Maximum Length of Vent Pipe System:
Electrical Rating:
Typical Room Size (3):
(1)
Heat and vaporized water are produced by the combustion process of this heater. This rating does not take
into account heat loss due to condensation of water vapor.
(2)
External tank to be purchased from local suppliers.
(3)
0˚ F Heat Load = 24 BTU/ft
20˚ F Heat Load = 20 BTU/ft
Room size for which this heater is suitable will vary depending on outside temperature, house
insulation, window size, and other factors.
2
Laser 730/Laser 730AT
92.4% (1)
High - 40,000 BTU/h
Med - 27,000 BTU/h
Low - 15,000 BTU/h
High - 0.301 gal/h (1.14 L/h)
Med - 0.203 gal/h (0.768 L/h)
Low - 0.113 gal/h (0.428 L/h)
External tank (2)
1-K kerosene (ASTM D3699)
Low Sulfur No.1 Fuel (ASTM D396 S500)
Ultra Low Sulfur Diesel Fuel (ULSD) or
Ultra Low Sulfur Heating Oil (ULSHO) (ASTM D975 S15)
30" × 27-1/2" × 16-3/4" (760 × 700 × 427 mm)
75 lbs. (34 kg) Empty
2-3/4" - 3" (7.0 - 7.5 cm) diameter
10 ft. (3 m), 3 bends or less
120 Volts AC, 60 Hz
Preheat - 260W
Burning - 50W
1670 square feet (0˚F)
2000 square feet (20˚F)
/hr
2
2
/hr